Yaseen Construction Products supplies Non Shrinking Grout for precision grouting beneath machinery baseplates, steel columns, equipment foundations and structural components.
Prepacked cementitious non-shrink grout is formulated to provide controlled flow, strength development and volume stability under specified mixing, placement and curing conditions. Suitable grades help establish continuous contact between load-bearing components and prepared concrete foundations.
Non Shrinking Grout, also called Non-Shrink Grout or Cementitious Precision Grout, is a prepacked hydraulic cement-based material used to fill gaps beneath equipment baseplates, steel structures and other components requiring stable support.
It is formulated to develop mechanical strength while controlling volume change during the specified placement and curing period.
Depending on the product, non-shrink grout may contain hydraulic cement, graded aggregates and performance-modifying admixtures that improve flow, strength development and dimensional stability.
It is commonly specified for machinery foundations, steel column baseplates, anchor bolts, precast connections and civil engineering applications.
Yaseen Construction Products sources non-shrink grout for industrial contractors, machinery installation specialists, structural steel contractors, infrastructure developers and project procurement teams.
A prepacked cement-based material used for precision grouting and filling confined spaces beneath structural or mechanical components.
Typical applications include:
Steel column baseplates.
Machinery foundations.
Equipment support plates.
Anchor bolt pockets.
Precast concrete connections.
Formulated to flow into suitable confined spaces under gravity or approved pumping conditions.
It is commonly selected where access is limited and continuous filling beneath baseplates is required.
Flow properties depend on the selected grade, water addition, temperature and placement conditions.
A stiffer grout consistency used for applications where flowable placement is unsuitable.
Plastic-consistency grout may be placed and compacted according to the manufacturer’s approved procedure.
Specialised grades formulated to achieve specified compressive strength at defined curing ages.
They are used where mechanical loading and structural support requirements demand particular strength performance.
High compressive strength alone does not establish suitability for every equipment foundation.
Selected formulations develop strength more quickly under specified conditions.
They may be suitable for maintenance shutdowns and equipment installations where early loading is required.
Actual loading times must be determined from the manufacturer’s strength-development data and engineering requirements.
| Parameter | Specification / Selection Criteria |
|---|---|
| Product | Non Shrinking Grout |
| Material Type | Prepacked Cementitious Grout |
| Binder | Hydraulic Cement-Based |
| Aggregate | Graded Mineral Aggregate |
| Consistency | Flowable, Plastic or Other Approved Grade |
| Mixing Water | Manufacturer-Specified Quantity |
| Fresh Density | According to selected product |
| Flow / Workability | Tested using applicable method |
| Working Time | Temperature and formulation dependent |
| Compressive Strength | Declared at specified curing ages |
| Flexural Strength | Grade dependent |
| Volume Change | According to applicable test method |
| Bleeding | Manufacturer and test dependent |
| Minimum Grout Thickness | Manufacturer specified |
| Maximum Grout Thickness | Manufacturer specified |
| Application Temperature | Manufacturer specified |
| Placement Method | Pouring, Pumping or Approved Packing |
| Curing | Manufacturer-specified procedure |
| Packaging | Prepacked Bags |
Actual strength, flow, thickness and volume-change values must be confirmed against the selected manufacturer’s technical data sheet.
Machinery baseplates and steel support components require effective contact with the underlying concrete foundation.
Uneven contact or unfilled gaps can concentrate loads and reduce the effectiveness of the support arrangement.
Non-shrink grout is placed into the prepared space to provide a continuous bearing interface after curing.
Its performance depends on:
Foundation preparation.
Grout gap dimensions.
Formwork arrangement.
Mixing water quantity.
Material flow.
Placement temperature.
Continuous pouring.
Curing conditions.
Equipment loading.
Anchor bolt and baseplate design.
Non-shrink grout is formulated to control volume change under defined conditions. It does not mean the material can never shrink or change dimensions during service.
Machinery installation requires careful control of baseplate support and alignment.
A typical grouting procedure involves:
Preparing the concrete foundation.
Cleaning the underside of the baseplate.
Setting equipment alignment and elevation.
Preparing sealed formwork.
Mixing the grout to the specified consistency.
Placing grout continuously from the approved pouring side.
Allowing the material to cure.
Completing equipment installation and loading according to the approved procedure.
For dynamically loaded equipment, the grout must also satisfy the mechanical and vibration-related requirements of the equipment manufacturer.
Confirm the approved grout grade.
Inspect foundation dimensions and grout thickness.
Remove laitance, loose concrete, oil and contaminants.
Prepare the concrete surface to the specified profile.
Clean baseplates, anchor pockets and contact surfaces.
Precondition the substrate according to the manufacturer’s instructions.
Install rigid, sealed formwork.
Provide suitable head boxes and venting arrangements where required.
Use clean water in the specified quantity.
Follow the manufacturer’s mixing sequence.
Use suitable mechanical mixing equipment.
Mix until the required consistency is achieved.
Do not add excessive water.
Do not remix material after the permitted working time.
Place grout within its working time.
Maintain a continuous pour where required.
Use the specified head pressure or pumping arrangement.
Avoid trapping air beneath baseplates.
Maintain the approved grout thickness.
Do not use uncontrolled vibration unless specifically permitted.
Protect exposed grout edges.
Begin curing according to the manufacturer’s instructions.
Prevent premature moisture loss.
Protect the grout from unsuitable temperatures.
Avoid early mechanical loading.
Remove formwork only after adequate strength development.
Inspect the completed grout installation.
| Property | Cementitious Non-Shrink Grout | Epoxy Grout | Free Flowing Micro Concrete |
|---|---|---|---|
| Binder | Hydraulic Cement | Epoxy Resin | Hydraulic Cement |
| Main Use | Precision Grouting and Load Transfer | Specialised Equipment and Industrial Grouting | Formed Concrete Reinstatement |
| Typical Placement | Beneath Baseplates and Into Confined Spaces | Beneath Equipment and Structural Components | Formed Repair Cavities |
| Chemical Resistance | Product dependent | Often selected for specific chemical exposure | Product dependent |
| Vibration Performance | Grade and design dependent | Grade and design dependent | Grade and design dependent |
| Temperature Limits | Manufacturer specified | Manufacturer specified | Manufacturer specified |
| Structural Suitability | Requires Approved Specification | Requires Approved Specification | Requires Approved Specification |
These products are not automatically interchangeable. Selection depends on equipment loads, grout thickness, operating temperature, chemical exposure and project requirements.
A properly designed grout installation provides a bearing interface between the supported component and the foundation.
Important considerations include:
Baseplate dimensions.
Bearing area.
Static and dynamic loads.
Anchor bolt arrangement.
Grout thickness.
Foundation strength.
Alignment tolerances.
Curing and strength development.
Long-term deformation.
Exposure conditions.
The grout should be selected as part of the complete equipment foundation or structural support design.
| Standard | Test / Requirement |
|---|---|
| ASTM C1107/C1107M | Packaged dry hydraulic-cement grout, nonshrink |
| ASTM C109/C109M | Compressive strength of hydraulic cement mortars |
| ASTM C939/C939M | Flow of grout using the flow cone method |
| ASTM C827/C827M | Change in height at early ages of cylindrical specimens of cementitious mixtures |
| ASTM C1090 | Measuring changes in height of cylindrical specimens of hydraulic-cement grout |
| ASTM C940 | Expansion and bleeding of freshly mixed grouts for preplaced-aggregate concrete |
| ASTM C157/C157M | Length change of hardened hydraulic-cement mortar and concrete |
ASTM C1107/C1107M is a key specification for packaged dry hydraulic-cement non-shrink grout. Compliance must be supported by the selected product’s documentation.
Buyers should confirm:
Type of equipment or structural component.
Static and dynamic loading.
Required compressive strength.
Grout gap thickness.
Flow or plastic consistency.
Working time.
Application temperature.
Early loading requirements.
Chemical or moisture exposure.
Applicable project standards.
Equipment manufacturer’s requirements.
For critical machinery foundations, the equipment supplier and responsible engineer should approve the grout specification and installation procedure.
Non-shrink grout is commonly supplied in prepacked bags.
Material quantity depends on:
Grout area.
Grout thickness.
Anchor pockets and recesses.
Manufacturer’s mixed yield.
Placement losses.
Formwork geometry.
Basic grout volume calculation:
Grout volume (m³) = Length (m) × Width (m) × Thickness (m)
Number of bags = Required grout volume ÷ Declared mixed yield per bag
Include the volume of anchor pockets and an appropriate allowance for site losses.
Yaseen Construction Products can review sourcing enquiries against recognised cementitious precision grout product ranges, including:
Fosroc Conbextra cementitious grout products.
SikaGrout cementitious non-shrink grout products.
MasterFlow cementitious precision grout products.
Other approved non-shrink grout manufacturers.
Equivalent products must be compared using compressive strength, flow, volume-change performance, grout thickness, working time, loading requirements and applicable standards.
Brand references are for technical comparison and product identification. They do not imply manufacturer affiliation, guaranteed availability or automatic equivalence.
Pricing depends on:
Cementitious formulation.
Strength grade.
Flow and placement characteristics.
Volume-change performance.
Bag weight and mixed yield.
Manufacturer.
Order quantity.
Delivery destination.
For meaningful procurement comparisons, buyers should evaluate the cost per cubic metre of placed grout using the declared mixed yield.
Yaseen Construction Products supplies and exports non-shrink grout for machinery foundations, steel structures, industrial facilities and infrastructure projects across the UAE, Saudi Arabia, Qatar, Oman, Kuwait and African countries, including Nigeria, Kenya, Ghana, Tanzania, Uganda, Ethiopia, South Africa, Egypt, Morocco, Rwanda, Zambia, Mozambique and Senegal.
We support industrial contractors, machinery installation companies, structural steel contractors, infrastructure developers and procurement teams with specification-based sourcing, bulk quotations and international shipment arrangements.
Product availability, pricing and delivery schedules depend on the selected grout grade, packaging, quantity and destination.
Controlled Volume Change: Formulated to meet specified non-shrink performance requirements under defined test conditions.
Effective Load Transfer: Provides a bearing interface between supported components and prepared foundations.
High-Strength Grades: Different formulations are available for specified compressive strength requirements.
Flowable Placement: Suitable grades can fill confined spaces beneath baseplates.
Prepacked Consistency: Factory-proportioned ingredients reduce variation associated with site batching.
Precision Grouting: Supports equipment alignment and installation where properly designed.
Early Strength Options: Selected products allow shorter waiting periods before approved loading.
Different Consistencies: Flowable and plastic grades accommodate different placement methods.
Anchor Bolt Applications: Suitable grades can fill approved anchor pockets and recesses.
Industrial Use: Applicable to machinery foundations and equipment installations.
Controlled Mixing: Manufacturer-defined water quantities support repeatable preparation.
Bulk Project Supply: Bagged materials can be procured according to calculated grout volumes.
Machinery Baseplates: Precision grouting beneath industrial equipment.
Steel Column Baseplates: Filling the bearing space between structural steel and concrete foundations.
Equipment Foundations: Grouting beneath pumps, compressors and other equipment where specified.
Anchor Bolt Pockets: Filling approved anchor recesses and pockets.
Precast Concrete Connections: Grouting selected structural connections.
Industrial Plants: Installation of process equipment and supporting structures.
Power Generation Facilities: Grouting of approved equipment foundations.
Water Treatment Plants: Baseplate and equipment grouting.
Infrastructure Construction: Structural grouting in civil engineering projects.
Warehouse and Factory Buildings: Steel support and equipment installation.
Heavy Engineering Facilities: Precision grouting under suitable machinery foundations.
Structural Support Systems: Filling specified gaps beneath load-bearing components.
Non Shrinking Grout is used beneath machinery baseplates, steel columns, equipment foundations and other structural components requiring stable support and effective load transfer. It is also used for approved anchor bolt pockets and confined grouting applications.
Non-shrink grout is a prepacked material formulated and tested for specific flow, strength and volume-change requirements. Ordinary site-mixed cement mortar may not provide the same controlled properties and should not automatically be substituted for precision grouting.
Not under every condition. Non-shrink grout is formulated to satisfy defined volume-change requirements under specified test conditions. Improper water addition, placement or curing can affect dimensional stability and performance.
Yes. Suitable grades are commonly used beneath machinery baseplates. For dynamically loaded equipment, the grout must satisfy the equipment manufacturer’s requirements for strength, deformation, vibration and operating conditions.
Compressive strength depends on the formulation, mixing water, curing temperature and testing age. Buyers should compare the manufacturer’s declared strength values against the project specification rather than assume a universal strength grade.
Cementitious grout uses hydraulic cement as its binder, while epoxy grout uses resin and hardener. Their mechanical properties, chemical resistance, temperature limits, placement requirements and cost differ. The correct material depends on the application and approved design.
Minimum and maximum grout thicknesses depend on the selected product and installation method. Excessively thin or thick placements may require a different grade or approved aggregate extension. Always follow the manufacturer’s thickness limits.
Use the exact water quantity or permitted range specified by the manufacturer for the required consistency. Excess water can reduce strength and affect bleeding, segregation and volume-change performance.
Yes. Cementitious grout generally requires appropriate curing to support hydration and reduce premature moisture loss. The curing method and duration should follow the manufacturer’s instructions and project specification.
Certain flowable grades can be pumped using suitable equipment and approved procedures. Pumping suitability depends on grout consistency, aggregate grading, working time and equipment configuration.
Pricing depends on strength grade, formulation, flow properties, volume-change performance, bag size, mixed yield, manufacturer, order quantity and delivery destination. The cost per cubic metre of placed grout is a useful procurement comparison.
Yaseen Construction Products supplies and exports non-shrink grout for construction, industrial equipment installation and infrastructure projects across the UAE, Saudi Arabia, Qatar, Oman, Kuwait and African countries, including Nigeria, Kenya, Ghana, Tanzania, Uganda, Ethiopia, South Africa, Egypt, Morocco, Rwanda, Zambia, Mozambique and Senegal.
We assist machinery installation contractors, structural steel contractors, industrial developers, infrastructure companies and procurement teams with specification matching, bulk quotations and international shipment arrangements.
Trusted supplier and exporter of building construction products in UAE, Saudi, Qatar, Oman & African Countries.
Still confused?
We are happy to help on our expertise with no conditions.