Images shown are for reference only. Product specifications, packaging, and appearance may differ based on brand or batch.
44.00 USD
Yaseen Construction Products supplies Solvent Free Epoxy for industrial flooring, concrete protection and selected commercial and infrastructure coating applications.
Solvent-free epoxy systems typically consist of an epoxy resin and hardener that chemically react to form a durable protective coating. Depending on the formulation, they can provide abrasion resistance, adhesion to prepared concrete and resistance to specified chemicals.
Solvent Free Epoxy is a resin-based coating system formulated without intentionally added organic solvents. It is commonly used to create protective finishes on properly prepared concrete and other approved substrates.
A typical two-component system contains an epoxy resin and a compatible hardener. Once mixed in the manufacturer’s specified ratio, the components react to form a crosslinked polymer coating.
Solvent-free epoxy coatings are widely used in industrial flooring, warehouses, manufacturing facilities, commercial buildings and selected infrastructure applications.
Depending on the formulation, the cured coating may provide abrasion resistance, resistance to specified chemicals, mechanical durability and a surface that can be cleaned using approved methods.
Yaseen Construction Products sources solvent-free epoxy coatings for industrial flooring contractors, protective coating applicators, civil engineering companies, facility maintenance teams and construction procurement departments.
A two-component coating designed for application to prepared concrete floors.
Typical applications include:
Industrial production areas.
Warehouses.
Commercial floors.
Equipment rooms.
Workshops.
Selected parking areas.
The required film thickness and number of coats depend on the approved flooring system.
A formulation designed to achieve a comparatively thick protective coating.
Selected products are used where higher film build, abrasion resistance or protective performance is required.
The allowable thickness per coat must follow the manufacturer’s instructions.
Certain solvent-free epoxy systems are formulated for self-smoothing floor finishes.
These may incorporate graded fillers or aggregates and are generally installed using specialised flooring tools.
A standard solvent-free epoxy coating should not automatically be treated as a self-levelling flooring system.
Specialised formulations are available for exposure to selected chemicals, oils and cleaning agents.
Chemical resistance depends on:
Chemical identity.
Concentration.
Temperature.
Exposure duration.
Cleaning procedures.
Coating thickness.
Selected epoxy systems are designed for protective coating applications on concrete or properly prepared metal.
Substrate preparation, primer selection, film thickness and exposure conditions must follow the product specification.
| Parameter | Specification / Selection Criteria |
|---|---|
| Product | Solvent Free Epoxy |
| Resin Type | Epoxy |
| Components | Typically Two-Component |
| Curing Agent | Manufacturer-Specified Hardener |
| Solvent Content | According to Formulation |
| Solids Content | Manufacturer Declared |
| VOC Content | Product-Specific Test or Declaration |
| Finish | Gloss, Semi-Gloss or Other Specified Finish |
| Colour | Manufacturer-Standard or Approved Colour |
| Mixing Ratio | Manufacturer Specified |
| Pot Life | Temperature Dependent |
| Working Time | Manufacturer Specified |
| Application Method | Roller, Squeegee, Trowel or Approved Equipment |
| Recommended Film Thickness | According to Coating System |
| Tack-Free Time | Manufacturer Specified |
| Overcoating Interval | Product and Temperature Dependent |
| Full Cure | Manufacturer Specified |
| Adhesion | Substrate and Preparation Dependent |
| Abrasion Resistance | Grade Dependent |
| Compressive Strength | Where Applicable to Filled Flooring Systems |
| Chemical Resistance | Product Specific |
| Service Temperature | Manufacturer Specified |
| Packaging | Pre-Proportioned Kits |
Actual performance values must be obtained from the selected manufacturer’s technical data sheet.
A solvent-free epoxy is formulated without intentionally added solvent used to reduce viscosity.
However, solvent-free does not automatically mean:
Zero VOC emissions.
Odour-free application.
Non-hazardous handling.
Food-contact approval.
Potable-water approval.
No ventilation requirement.
No chemical exposure risk.
Reactive diluents and other formulation components may still affect emissions and handling requirements.
The product’s safety data sheet and declared VOC content should be checked before selection.
The epoxy resin and hardener undergo a chemical curing reaction after mixing.
The resulting coating bonds to the prepared substrate and forms a protective surface.
Performance depends on:
Correct resin-to-hardener ratio.
Thorough mixing.
Concrete surface preparation.
Substrate moisture.
Application temperature.
Relative humidity.
Coating thickness.
Pot life.
Overcoating intervals.
Curing conditions.
Intended mechanical and chemical exposure.
Incorrect mixing or unsuitable substrate conditions can cause incomplete curing, poor adhesion or coating defects.
| Property | Solvent Free Epoxy | Solvent Based Epoxy | Water Based Epoxy |
|---|---|---|---|
| Carrier | No Intentionally Added Solvent | Organic Solvent | Water |
| Solids Content | Often High | Formulation Dependent | Formulation Dependent |
| VOC Content | Must Be Verified | Must Be Verified | Must Be Verified |
| Application Viscosity | Product Dependent | Product Dependent | Product Dependent |
| Film Build | Product Dependent | Product Dependent | Product Dependent |
| Concrete Flooring Use | Common | Common in Selected Systems | Common in Selected Systems |
| Chemical Resistance | Grade Dependent | Grade Dependent | Grade Dependent |
| Ventilation | Still Required as Specified | Required as Specified | Required as Specified |
The best system depends on the substrate, environmental conditions, coating performance and project specification.
A typical industrial epoxy flooring system may include:
Concrete surface inspection.
Mechanical surface preparation.
Cleaning and dust removal.
Moisture assessment.
Concrete crack and defect repairs.
Application of a compatible primer.
Mixing of the epoxy components.
Application of the specified epoxy coating.
Additional coats or aggregate broadcast where required.
Curing and final inspection.
The actual installation sequence depends on the manufacturer’s approved system.
Surface preparation is essential for reliable epoxy coating performance.
Concrete should be:
Sound and structurally suitable.
Free from loose material.
Free from oil, grease and incompatible contaminants.
Prepared to the required surface profile.
Within the manufacturer’s moisture limits.
Free from uncontrolled moisture transmission.
Suitable for the specified primer and coating.
Mechanical preparation methods may include grinding or shot blasting, depending on the coating system.
The required surface profile should be specified using the relevant industry method.
Check the product shelf life.
Confirm the resin and hardener are the correct matched components.
Verify the application temperature.
Confirm substrate preparation and moisture conditions.
Prepare the required application tools.
Mix the components in the specified ratio.
Follow the manufacturer’s mixing sequence.
Use suitable mechanical mixing equipment.
Avoid excessive air entrainment.
Do not add unapproved solvent or thinner.
Apply within the declared pot life.
Apply the coating at the specified film thickness.
Maintain uniform coverage.
Observe overcoating intervals.
Avoid contamination between coats.
Use the approved aggregate broadcast method where required.
Protect the coating during curing.
Selected solvent-free epoxy coatings are designed for floors exposed to pedestrian traffic, wheeled equipment and industrial activity.
Performance depends on:
Coating thickness.
Resin formulation.
Aggregate content.
Substrate strength.
Wheel loading.
Impact exposure.
Surface maintenance.
A thin epoxy coating should not be treated as equivalent to a thick resin screed or heavy-duty industrial flooring system.
Chemical-resistant epoxy systems are selected according to the actual exposure conditions.
Buyers should provide:
Chemical name.
Concentration.
Temperature.
Exposure duration.
Frequency of spills.
Cleaning procedures.
Required coating thickness.
The manufacturer’s chemical resistance chart should be reviewed before approving the coating.
Many conventional epoxy coatings can yellow, chalk or discolour under prolonged sunlight.
For exterior applications or locations requiring strong colour retention, a compatible UV-resistant topcoat may be required.
The complete coating system must be approved for the intended exposure.
Smooth epoxy flooring can become slippery when wet or contaminated.
Where slip resistance is required, the flooring specification may include:
Graded quartz aggregate.
Approved antislip additives.
Textured application methods.
Suitable topcoats.
Slip resistance must be assessed on the finished flooring system rather than the resin alone.
| Standard | Test / Requirement |
|---|---|
| ASTM D4541 | Pull-off strength of coatings using portable adhesion testers |
| ASTM D4060 | Abrasion resistance of organic coatings by Taber abraser |
| ASTM D3363 | Film hardness by pencil test |
| ASTM D2240 | Durometer hardness, where applicable |
| ASTM D2369 | Volatile content of coatings |
| ASTM D3960 | Determining VOC content of paints and related coatings |
| ASTM D7234 | Pull-off adhesion strength of coatings on concrete |
| ASTM F2170 | Relative humidity in concrete floor slabs |
| ISO 2812 | Resistance to liquids |
| ISO 4624 | Pull-off adhesion test for coatings |
Applicable standards depend on the coating system, substrate and project requirements. Compliance must be supported by manufacturer documentation.
Buyers should confirm:
Floor or substrate type.
Required coating thickness.
Mechanical loading.
Chemical exposure.
Surface finish.
Slip-resistance requirements.
Substrate moisture.
Application temperature.
Required curing period.
UV exposure.
Maintenance requirements.
Applicable project standards.
For industrial flooring, selection should consider the complete primer, coating, aggregate and topcoat system.
Solvent-free epoxy coatings are generally supplied in pre-proportioned resin and hardener kits.
Material consumption depends on:
Coating thickness.
Surface porosity.
Surface profile.
Solids content.
Application method.
Aggregate broadcast.
Material losses.
For a theoretical 100% volume-solids coating:
Volume (litres) = Area (m²) × Dry film thickness (mm)
For example, a 100 m² floor at a dry film thickness of 0.5 mm requires a theoretical coating volume of 50 litres before allowing for surface profile, losses and other system requirements.
For products with lower volume solids, consumption must be adjusted using the manufacturer’s declared volume-solids percentage.
Yaseen Construction Products can review sourcing requirements against relevant solvent-free epoxy product ranges, including:
Sika Sikafloor epoxy flooring systems.
Fosroc Nitoflor epoxy flooring systems.
Flowcrete epoxy flooring systems.
Other approved industrial epoxy coating manufacturers.
Equivalent products must be compared using solids content, film thickness, adhesion, abrasion resistance, chemical resistance, curing conditions and intended service environment.
Brand references are for technical comparison and product identification. They do not imply manufacturer affiliation, guaranteed availability or automatic equivalence.
Pricing depends on:
Resin formulation.
Solids content.
Chemical resistance.
Required film thickness.
Colour and finish.
Kit size.
Manufacturer.
Order quantity.
Delivery destination.
For accurate quotations, buyers should provide the floor area, required coating thickness, substrate condition, expected exposure and approved specification.
Yaseen Construction Products supplies and exports solvent-free epoxy coatings for industrial flooring, concrete protection, commercial buildings and infrastructure projects across the UAE, Saudi Arabia, Qatar, Oman, Kuwait and African countries, including Nigeria, Kenya, Ghana, Tanzania, Uganda, Ethiopia, South Africa, Egypt, Morocco, Rwanda, Zambia, Mozambique and Senegal.
We support industrial flooring contractors, protective coating applicators, civil engineering companies, facility maintenance teams and procurement departments with specification-based sourcing, bulk quotations and international shipment arrangements.
Product availability, pricing and delivery schedules depend on formulation, packaging, quantity and destination.
High-Solids Options: Many formulations provide high film build with limited volatile carrier content.
Concrete Protection: Forms a protective coating over properly prepared concrete.
Abrasion Resistance: Suitable grades withstand specified industrial wear.
Chemical Resistance: Specialised formulations resist selected chemicals and cleaning agents.
Industrial Flooring Use: Commonly used in factories, warehouses and workshops.
Seamless Surface: Can form a continuous finish across prepared floor areas.
Different Surface Finishes: Gloss, textured and other finishes are available through approved systems.
Antislip Options: Compatible quartz aggregates can be used to create textured flooring.
Mechanical Durability: Selected grades withstand specified traffic and loading conditions.
Cleaning and Maintenance: Properly cured surfaces can be cleaned using approved procedures.
System Flexibility: Available as coatings, high-build systems and selected self-smoothing formulations.
Bulk Project Supply: Suitable for specification-based procurement across industrial and commercial developments.
Industrial Flooring: Protective coatings for manufacturing and production areas.
Warehouse Floors: Coating systems for specified storage and traffic conditions.
Commercial Buildings: Durable resin flooring in approved interior areas.
Workshops: Protective floor finishes for maintenance facilities.
Equipment Rooms: Coatings for compatible concrete surfaces.
Parking Structures: Selected epoxy flooring systems for approved traffic conditions.
Pharmaceutical Facilities: Flooring systems selected according to hygiene and cleaning requirements.
Food Processing Facilities: Approved coating systems for specified cleaning and chemical exposure.
Chemical Processing Areas: Specialised formulations for defined chemical exposure.
Utility Buildings: Protective coatings for concrete floors and surfaces.
Infrastructure Facilities: Concrete protection in approved service environments.
Industrial Maintenance: Recoating and refurbishment of suitable existing floors.
Solvent Free Epoxy is used for industrial flooring, concrete protection and selected protective coating applications. It is commonly specified for factories, warehouses, workshops and commercial facilities requiring a durable resin coating.
Solvent-free epoxy is formulated without intentionally added organic solvent used as a carrier or thinner. It does not automatically mean zero VOC emissions, odour-free application or hazard-free handling. The manufacturer’s technical and safety data should be reviewed.
Yes. Suitable solvent-free epoxy systems are commonly used for industrial concrete floors. The required coating thickness, abrasion resistance, mechanical loading and chemical exposure must be considered.
Solvent-free epoxy generally relies on reactive components without intentionally added solvent, while solvent-based epoxy contains an organic solvent carrier. Their application viscosity, solids content, drying behaviour and coating performance vary by formulation.
Some products are designed for direct application, while others require a compatible primer. The concrete must meet the manufacturer’s requirements for strength, moisture, surface profile and cleanliness.
Primer requirements depend on the coating system and substrate condition. Porous concrete, weak surfaces or specialised exposure conditions may require a specific primer. Follow the approved flooring specification
Curing time depends on the resin formulation, hardener, temperature, coating thickness and service requirements. The manufacturer’s stated pot life, overcoating interval, foot-traffic time and full cure period should be followed.
Some systems may be approved for exterior applications, but conventional epoxy coatings can yellow or chalk under prolonged UV exposure. A compatible UV-resistant topcoat may be necessary.
A smooth epoxy coating is not automatically slip-resistant, especially when wet. Textured flooring systems can incorporate graded quartz or approved antislip additives. The completed floor should meet the specified slip-resistance requirement.
Pricing depends on formulation, solids content, coating thickness, chemical resistance, colour, packaging, manufacturer, order quantity and delivery destination. Buyers should compare the cost of the complete specified coating system per square metre.
Selected formulations provide resistance to specified chemicals, oils and cleaning agents. Resistance depends on concentration, temperature and exposure duration. Product-specific chemical resistance data is required.
Yaseen Construction Products supplies and exports solvent-free epoxy coatings for industrial flooring, commercial buildings, concrete protection and infrastructure projects across the UAE, Saudi Arabia, Qatar, Oman, Kuwait and African countries, including Nigeria, Kenya, Ghana, Tanzania, Uganda, Ethiopia, South Africa, Egypt, Morocco, Rwanda, Zambia, Mozambique and Senegal.
We assist industrial flooring contractors, protective coating applicators, civil engineering companies, facility maintenance teams and procurement departments with specification matching, bulk quotations and international shipment arrangements.
Trusted supplier and exporter of building construction products in UAE, Saudi, Qatar, Oman & African Countries.
Still confused?
We are happy to help on our expertise with no conditions.