Images shown are for reference only. Product specifications, packaging, and appearance may differ based on brand or batch.
40.00 USD
Yaseen Construction Products supplies Polyurethane Waterproofing Coatings for roofs, terraces, balconies, podium decks and other approved concrete waterproofing applications.
Polyurethane (PU) waterproofing coatings are liquid-applied materials that form a continuous elastomeric membrane after curing. Available systems include single-component, two-component, exposed and protected grades, with different curing mechanisms, crack-bridging properties and performance requirements.
Polyurethane Waterproofing Coating is a liquid-applied protective material used to create a continuous waterproofing membrane over suitable construction substrates.
Polyurethane coatings are based on reactive polymer chemistry. Depending on the formulation, they cure through atmospheric moisture, chemical reaction between components or another manufacturer-specified mechanism.
Once properly applied and cured, suitable polyurethane systems form a flexible waterproofing membrane that can accommodate specified substrate movement and resist water penetration.
Yaseen Construction Products sources polyurethane waterproofing coatings for roofing contractors, waterproofing specialists, civil engineering companies, property developers and industrial construction projects.
Polyurethane Waterproofing Coating is a liquid material that cures to form a protective polymer membrane.
Construction waterproofing grades may provide:
Resistance to water penetration.
Seamless coverage across open areas.
Flexibility.
Tested crack-bridging performance.
Adhesion to compatible substrates.
Weather resistance in approved exposed systems.
Compatibility with reinforcement and protective layers.
Performance depends on the formulation, substrate, primer, dry film thickness and curing conditions.
Polyurethane coating should not be treated as one universal product type. Decorative PU coatings, traffic coatings and waterproofing membranes have different performance requirements.
The liquid coating is applied to a prepared substrate at a specified wet film thickness.
During curing, the material develops a continuous polyurethane membrane.
The membrane’s effectiveness depends on:
Substrate preparation.
Primer selection.
Coating thickness.
Correct mixing where applicable.
Environmental conditions.
Complete curing.
Joint and penetration detailing.
Reinforcement where required.
Protection against unsuitable exposure.
A coating applied below the specified thickness may not achieve its intended waterproofing performance.
Single-component PU coatings are supplied ready for application, subject to manufacturer mixing instructions.
Many moisture-curing formulations react with atmospheric moisture to form a membrane.
Application requirements may include specific humidity, substrate moisture and temperature limits.
Two-component PU coatings contain separate components that are mixed before application.
Their performance depends on correct mixing ratio, mixing procedure and application within the specified pot life.
Moisture-curing polyurethane systems use atmospheric moisture as part of the curing reaction.
Excessive substrate moisture or unsuitable application conditions may cause defects in some formulations.
Selected polyurethane coatings are supplied as water-based dispersions or related formulations.
Their drying and curing behaviour differs from solvent-based and reactive moisture-curing systems.
Some PU coatings contain solvents.
Application requires appropriate ventilation, safety precautions and compliance with the manufacturer’s safety data sheet.
Selected polyurethane systems are formulated for exposed exterior use.
UV resistance must be verified using the actual product’s performance data.
Some aromatic polyurethane membranes require a compatible protective topcoat where colour stability or long-term exposed performance is specified.
Aliphatic polyurethane topcoats are commonly selected where colour retention and exterior weathering performance are required.
A topcoat is not automatically a standalone waterproofing membrane.
Traffic-bearing PU systems are designed for specified pedestrian or vehicle loading.
They may incorporate additional layers, aggregates and protective topcoats.
Ordinary roof waterproofing coatings should not be used as traffic-bearing systems without approval.
| Parameter | Specification / Selection Criteria |
|---|---|
| Product | Polyurethane Waterproofing Coating |
| Material Type | Liquid-Applied Polyurethane |
| Components | Single-Component or Two-Component |
| Chemistry | Manufacturer Specified |
| Colour | Manufacturer Standard Colours |
| Physical Form | Liquid |
| Density | Manufacturer Declared |
| Solids Content | Manufacturer Declared |
| Viscosity | Manufacturer Declared |
| Pot Life | For Applicable Two-Component Products |
| Tack-Free Time | Manufacturer Specified |
| Recoat Interval | Manufacturer Specified |
| Full Cure Time | Manufacturer Specified |
| Recommended Dry Film Thickness | Manufacturer Specified |
| Coverage | Manufacturer Declared |
| Tensile Strength | Manufacturer Declared |
| Elongation at Break | Manufacturer Declared |
| Crack-Bridging Performance | Where Tested |
| Adhesion Strength | Manufacturer Declared |
| Watertightness | Manufacturer Declared |
| Water Vapour Permeability | Where Relevant |
| UV Resistance | Where Applicable |
| Abrasion Resistance | For Traffic-Grade Systems |
| Application Temperature | Manufacturer Specified |
| Substrate Moisture Limit | Manufacturer Specified |
| Packaging | Pails, Drums or Component Kits |
Actual technical values must be confirmed using the selected manufacturer’s technical data sheet and test documentation.
| Property | Polyurethane Coating | Acrylic Waterproofing Coating |
|---|---|---|
| Main Binder | Polyurethane Polymer | Acrylic Polymer |
| Curing | Moisture, Chemical Reaction or Other Specified Mechanism | Commonly Water Evaporation and Film Formation |
| Flexibility | Product Dependent | Product Dependent |
| Crack Bridging | Available in Tested Grades | Available in Tested Grades |
| UV Resistance | Grade Dependent | Grade Dependent |
| Ponding Water Resistance | Requires Specific Approval | Requires Specific Approval |
| Substrate Moisture Tolerance | Product Dependent | Product Dependent |
| Typical Applications | Roofs, Terraces and Specialised Waterproofing | Roofs and Exterior Protective Coatings |
Neither system is universally superior. The correct choice depends on exposure, substrate, required membrane thickness and tested performance.
Acrylic cementitious coatings combine cement-based components with polymer modification.
They are commonly used in selected concrete and masonry waterproofing applications.
Polyurethane coatings form polymer membranes through their specific curing mechanism.
The two systems differ in:
Substrate compatibility.
Curing behaviour.
Flexibility.
Surface preparation.
Moisture tolerance.
Exposure suitability.
Rubberized bitumen emulsions use bituminous binders modified with rubber or elastomeric materials.
Polyurethane coatings use polyurethane polymer chemistry.
Both may be liquid-applied, but their curing mechanisms, UV resistance, chemical compatibility and mechanical properties differ.
Below-ground bituminous coatings should not automatically be replaced with polyurethane coatings, or vice versa, without reviewing the waterproofing design.
| Property | Polyurethane Coating | Sheet Membrane |
|---|---|---|
| Product Form | Liquid | Prefabricated Roll |
| Application | Brush, Roller, Squeegee or Spray | Torch, Self Adhesive or Other Method |
| Joints | Generally Seamless Across Open Areas | Requires Laps |
| Thickness | Controlled During Application | Factory-Manufactured |
| Complex Geometry | Can Be Suitable for Irregular Details | Requires Cutting and Joint Detailing |
| Curing | Required | Product-Specific |
| Quality Control | Film Thickness and Cure | Bonding, Laps and Continuity |
Polyurethane coatings are used in approved flat and low-slope roof waterproofing systems.
Selection should consider:
Roof drainage.
Substrate movement.
UV exposure.
Standing water.
Insulation compatibility.
Coating thickness.
Maintenance access.
Protective topcoat requirements.
A product must be approved for the actual roof conditions.
Suitable PU systems may be applied to terraces and roof decks.
Terrace waterproofing must address:
Surface falls.
Drainage outlets.
Parapet junctions.
Door thresholds.
Movement joints.
Pedestrian traffic.
Protective finishes.
An ordinary PU waterproofing membrane should not be left exposed to regular foot traffic unless the system is approved for that use.
Balconies require careful detailing at:
Door thresholds.
Drainage outlets.
Wall junctions.
Railings.
Penetrations.
Movement joints.
Suitable polyurethane systems can provide waterproofing when integrated with the approved balcony construction.
Podium waterproofing systems may require resistance to structural movement and subsequent construction loading.
Selected PU membranes may be used beneath protective screeds or other approved layers.
Traffic-bearing areas require a system specifically designed for the expected loading.
Polyurethane waterproofing coatings may be applied to properly prepared concrete.
The concrete should satisfy the manufacturer’s requirements for:
Surface strength.
Moisture content.
Curing.
Surface profile.
Cleanliness.
Temperature.
Selected PU systems may be used in:
Bathrooms.
Shower areas.
Utility rooms.
Commercial wet areas.
Other approved interior waterproofing applications.
Compatibility with screeds, tile adhesives and finishes must be verified.
Certain polyurethane systems are approved for below-ground waterproofing.
However, not every roof-grade PU coating is suitable for:
Sustained hydrostatic pressure.
Groundwater exposure.
Backfilling.
Negative-side water pressure.
The selected system must be approved for the actual exposure.
Polyurethane floor coatings are available for industrial environments, but they are a separate performance category from ordinary liquid-applied waterproofing membranes.
Industrial flooring systems may require:
Abrasion resistance.
Chemical resistance.
Impact resistance.
Slip resistance.
Traffic loading performance.
A roof waterproofing membrane should not be substituted for an industrial floor coating.
Selected polyurethane membranes provide tested crack-bridging performance.
Selection should consider:
Existing crack width.
Expected movement.
Temperature.
Membrane thickness.
Reinforcement.
Crack-bridging classification.
Structural cracks and active movement joints require appropriate repair or detailing.
Some polyurethane systems use reinforcement at:
Corners.
Junctions.
Penetrations.
Drains.
Cracks.
Changes in substrate.
Other systems specify full-surface reinforcement.
Compatible polyester fleece or other manufacturer-approved reinforcement may be used.
Fibreglass reinforcement should not be substituted without system approval.
Before application:
Remove dust and debris.
Remove oil and contaminants.
Remove weak concrete.
Repair surface defects.
Prepare cracks and joints.
Check substrate moisture.
Confirm surface strength.
Apply the approved primer.
Verify application conditions.
Confirm the coating grade, primer, reinforcement, thickness and exposure requirements.
Complete cleaning, repairs and surface profiling.
Verify that substrate moisture and ambient conditions meet manufacturer limits.
Use the approved primer and allow it to reach the required application condition.
For single-component products, mix as instructed.
For two-component products, combine the components in the specified ratio.
Apply using the approved method and maintain the required wet film thickness.
Embed approved reinforcement at specified junctions or across the full area where required.
Follow the manufacturer’s recoat intervals and application thickness requirements.
Use the specified UV-resistant or traffic-resistant topcoat where required.
Check membrane continuity, film thickness, adhesion where specified and full curing before exposure or covering.
Possible causes include:
Excessive substrate moisture.
Trapped vapour.
Incorrect primer.
Unsuitable application conditions.
Possible causes include:
Porous substrates.
Outgassing.
Inadequate primer.
Incorrect application.
Possible causes include:
Weak substrate.
Dust.
Contamination.
Incorrect moisture conditions.
Incompatible primer.
Possible causes include:
Incorrect mixing ratio.
Unsuitable temperature.
Humidity outside the approved range.
Expired material.
Incorrect application thickness.
Possible causes include:
Substrate movement.
Inadequate membrane thickness.
Incorrect grade.
Poor joint detailing.
Some aromatic polyurethane systems may discolour under UV exposure.
Discolouration does not always mean waterproofing failure, but it may indicate that the wrong exposed finish was selected.
| Standard | Application |
|---|---|
| ETAG 005 / Applicable EAD | Assessment framework for liquid-applied roof waterproofing kits |
| EN 14891 | Liquid-applied water-impermeable products beneath ceramic tiling |
| EN 1504-2 | Surface protection systems for concrete, where applicable |
| ASTM C836/C836M | High-solids-content, cold liquid-applied elastomeric waterproofing membrane for use with separate wearing course |
| ASTM D412 | Tensile properties of rubber and elastomers, where applicable |
| ASTM D4541 | Pull-off strength of coatings using portable adhesion testers |
| ISO 2808 | Film thickness determination |
| ISO 2811-1 | Density determination |
| ISO 3251 | Non-volatile matter content |
These standards apply to different product categories and test methods. Compliance must be confirmed for the actual polyurethane formulation and intended use.
Buyers should confirm:
Roofing or below-ground application.
Exposed or protected system.
Single-component or two-component formulation.
Moisture-curing or other curing mechanism.
UV resistance.
Standing water exposure.
Required dry film thickness.
Crack-bridging performance.
Tensile strength.
Elongation.
Adhesion.
Substrate compatibility.
Primer requirements.
Reinforcement.
Topcoat requirements.
Traffic loading.
Packaging.
Project quantity.
Polyurethane waterproofing coatings are commonly supplied in pails, drums or two-component kits.
Consumption depends on:
Surface area.
Substrate porosity.
Solids content.
Required dry film thickness.
Number of coats.
Reinforcement.
Application losses.
Theoretical wet consumption (L/m²) = Required dry film thickness (mm) ÷ Volume solids fraction
For example, a coating with an assumed 80% volume solids applied at 1.5 mm total dry film thickness requires approximately 1.875 L/m² before losses.
For a 400 m² project:
Theoretical volume: 750 litres.
With an illustrative 10% allowance: 825 litres.
Actual consumption must follow the selected manufacturer’s declared coverage. Conversion from litres to kilograms requires the product’s density.
Yaseen Construction Products can review sourcing enquiries against relevant polyurethane waterproofing systems from manufacturers such as:
Sika Sikalastic polyurethane waterproofing systems.
Fosroc Nitoproof polyurethane waterproofing products.
Mapei polyurethane waterproofing systems.
Other approved liquid-applied waterproofing manufacturers.
Brand references are for technical comparison and product identification only. They do not imply manufacturer affiliation, guaranteed availability or direct equivalence.
Equivalent products must be compared using chemistry, curing mechanism, membrane thickness, UV resistance, crack-bridging performance, adhesion and intended application.
Pricing depends on:
Formulation.
Single-component or two-component system.
Solids content.
Required membrane thickness.
UV resistance.
Crack-bridging performance.
Primer and reinforcement.
Topcoat requirements.
Manufacturer.
Packaging.
Order quantity.
Delivery destination.
For project comparisons, evaluate the complete installed system cost per square metre rather than price per kilogram alone.
For a specification-based quotation, provide:
Project location.
Roof, terrace, balcony or below-ground application.
Substrate type.
Exposed or protected system.
Required dry film thickness.
Relevant technical standard.
Surface area.
Primer and reinforcement requirements.
UV or traffic exposure.
Required quantity.
Packaging preference.
Delivery destination.
Delivery schedule.
Yaseen Construction Products supplies and exports polyurethane waterproofing coatings for roofs, terraces, balconies, podium decks, concrete structures and approved below-ground waterproofing systems across the UAE, Saudi Arabia, Qatar, Oman, Kuwait and African countries, including Nigeria, Kenya, Ghana, Tanzania, Uganda, Ethiopia, South Africa, Egypt, Morocco, Rwanda, Zambia, Mozambique and Senegal.
We support waterproofing contractors, roofing specialists, civil engineering companies, property developers, industrial construction companies and procurement teams with specification-based sourcing, bulk quotations and international shipment arrangements.
Product availability, pricing and delivery schedules depend on formulation, packaging, quantity and destination.
Seamless Waterproofing: Forms a continuous membrane across properly prepared open surfaces.
Flexible Membrane: Suitable formulations accommodate specified substrate movement.
Crack-Bridging Options: Tested grades provide defined crack-bridging performance.
Liquid Application: Suitable for approved complex roof and terrace details.
Multiple Formulations: Single-component and two-component systems are available.
UV-Resistant Options: Selected grades are designed for exposed exterior applications.
Different Application Methods: Approved products may be applied by brush, roller, squeegee or spray.
Concrete Compatibility: Suitable grades bond to properly prepared concrete substrates.
Reinforcement Options: Compatible systems may use local or full-surface reinforcement.
Protective Topcoats: Approved topcoats can provide additional weathering or traffic performance.
Project-Specific Thickness: Membrane thickness can be specified according to system requirements.
Bulk Project Procurement: Suitable for commercial roofing, terraces, podium decks and infrastructure projects.
Flat Roofs: Liquid-applied waterproofing for approved roof systems.
Terraces: Waterproofing beneath compatible finishes or approved exposed systems.
Balconies: Waterproofing at floors, thresholds and drainage details.
Podium Decks: Protected waterproofing systems beneath approved overburden.
Concrete Roof Slabs: Waterproofing of properly prepared concrete surfaces.
Roof Upstands: Waterproofing of parapets and vertical junctions.
Drainage Outlets: Reinforced waterproofing around approved roof drainage details.
Wet Areas: Selected bathroom, shower and utility-area waterproofing systems.
Commercial Buildings: Roof and terrace waterproofing.
Residential Developments: Waterproofing for villas and apartment projects.
Below-Ground Structures: Application-specific PU waterproofing systems.
Traffic-Bearing Decks: Specialised polyurethane systems designed for pedestrian or vehicle loading.
Polyurethane Waterproofing Coating is a liquid-applied material that cures to form a continuous polymer membrane. Suitable formulations are used to protect roofs, terraces, balconies and other approved construction surfaces against water penetration.
It is used for roof waterproofing, terraces, balconies, podium decks, wet areas and selected below-ground structures. The correct grade depends on exposure, substrate, movement and required membrane performance.
Suitable polyurethane waterproofing systems provide resistance to water penetration when applied at the specified thickness and fully cured. Performance depends on the formulation, surface preparation, detailing and intended exposure.
Single-component products are supplied in one container and cure according to their formulation, often using atmospheric moisture. Two-component products require mixing separate components in a specified ratio before application.
Yes. Suitable PU waterproofing systems are used on flat and low-slope roofs. The product must be approved for UV exposure, drainage conditions, standing water and the intended roof assembly.
Some polyurethane coatings are formulated for exposed UV conditions, while others require a compatible protective topcoat. UV resistance must be confirmed for the selected product.
Not automatically. Many PU systems have strict substrate moisture limits. Application to damp or wet concrete requires a product and primer system specifically approved for those conditions.
Selected polyurethane waterproofing membranes offer tested crack-bridging performance. The allowable movement depends on membrane thickness, temperature, reinforcement and the specific product.
Polyurethane and acrylic coatings use different polymer chemistry and curing mechanisms. Their flexibility, UV resistance, moisture tolerance and waterproofing performance depend on the formulation and approved application.
Curing time depends on the product, film thickness, temperature, humidity and ventilation. The manufacturer’s technical data sheet should be used to determine recoating, foot traffic and full-service exposure times.
Consumption depends on volume solids and required dry film thickness. For example, a product with an assumed 80% volume solids applied at 1.5 mm dry film thickness requires approximately 1.875 litres/m² before losses. Actual consumption must follow manufacturer data.
Yaseen Construction Products supplies and exports polyurethane waterproofing coatings for roofs, terraces, balconies, podium decks and approved concrete waterproofing systems across the UAE, Saudi Arabia, Qatar, Oman, Kuwait and African countries, including Nigeria, Kenya, Ghana, Tanzania, Uganda, Ethiopia, South Africa, Egypt, Morocco, Rwanda, Zambia, Mozambique and Senegal.
We assist waterproofing contractors, roofing specialists, civil engineering companies, property developers and procurement teams with specification matching, bulk quotations and international shipment arrangements.
Trusted supplier and exporter of building construction products in UAE, Saudi, Qatar, Oman & African Countries.
Still confused?
We are happy to help on our expertise with no conditions.