Images shown are for reference only. Product specifications, packaging, and appearance may differ based on brand or batch.
6.00 USD
Yaseen Construction Products supplies Extruded Polystyrene (XPS) insulation boards for commercial buildings, industrial facilities, infrastructure and residential developments. XPS is a rigid, closed-cell thermal insulation material used in roofs, walls, floors and below-grade construction.
We source XPS boards according to project requirements for thickness, thermal conductivity, compressive strength, water absorption, edge profile and board dimensions
Extruded Polystyrene (XPS) is a rigid thermoplastic foam insulation manufactured through an extrusion process that produces a predominantly closed-cell structure. Its combination of low thermal conductivity, moisture resistance and compressive strength makes it suitable for building-envelope insulation and selected load-bearing applications.
XPS boards help reduce heat transfer through roofs, walls, floors and foundations. In warm climates, properly designed insulation systems can reduce unwanted heat gain and improve building energy performance.
Yaseen Construction Products sources XPS insulation boards for commercial developments, residential buildings, industrial facilities, cold-storage projects and infrastructure construction. We support specification-based procurement, including requirements for board thickness, thermal resistance, compressive strength, edge configuration and applicable building standards.
Rigid boards designed for general thermal insulation applications in compatible building systems. These are commonly specified for roofs, floors and walls where the required thermal and mechanical performance can be achieved.
Engineered for applications where insulation must resist sustained or temporary compressive loads.
Typical uses include ground-bearing floors, foundation insulation and selected heavily loaded roof assemblies. Long-term compressive creep performance must be considered in addition to short-term compressive strength.
In protected membrane or inverted roof systems, XPS boards are installed above the waterproofing membrane.
The insulation must be suitable for the expected moisture exposure, roof loading and drainage arrangement. System design should account for water flow, thermal performance and protective ballast or paving.
Selected XPS grades can be incorporated into cavity walls, external insulation systems and other approved wall assemblies.
Compatibility with adhesives, render systems, fire-safety requirements and facade specifications must be verified before installation.
| Parameter | Specification / Selection Criteria |
|---|---|
| Product | Extruded Polystyrene (XPS) Board |
| Material | Extruded Polystyrene Foam |
| Cellular Structure | Predominantly Closed-Cell |
| Standard Listed Sheet Size | 600 × 1000 mm |
| Listed Density | 32–35 kg/m³ |
| Thickness | Manufacturer and project dependent |
| Thermal Conductivity (λ) | W/(m·K), according to product grade |
| Thermal Resistance (R) | m²·K/W, dependent on thickness and declared conductivity |
| Compressive Strength | kPa, according to grade and test method |
| Water Absorption | According to specified immersion test |
| Water Vapour Resistance | Grade and test-method dependent |
| Dimensional Stability | According to temperature and humidity test conditions |
| Edge Profile | Square, shiplap or tongue-and-groove, where available |
| Reaction to Fire | Product and assembly dependent |
| Supply Form | Rigid Insulation Boards |
The existing Yaseen listing specifies a 600 × 1000 mm sheet and density of 32–35 kg/m³. Other properties must be verified against the selected manufacturer’s technical data sheet.
The effectiveness of XPS insulation is determined primarily by its declared thermal conductivity and installed thickness.
Thermal resistance is calculated as:
R = Thickness (m) ÷ Thermal Conductivity (W/m·K)
For example, an XPS board with a thickness of 50 mm and an assumed thermal conductivity of 0.034 W/(m·K) has a calculated material thermal resistance of approximately 1.47 m²·K/W.
This is an illustrative calculation, not a declared performance value for a specific Yaseen-supplied board. Actual design values should follow the selected manufacturer’s documentation and applicable building regulations.
| Property | XPS | EPS | Mineral Wool |
|---|---|---|---|
| Material | Extruded Polystyrene | Expanded Polystyrene | Glass or Stone Mineral Fibers |
| Structure | Predominantly Closed-Cell Foam | Fused Expanded Foam Beads | Fibrous |
| Thermal Insulation | Good | Good | Good |
| Moisture Resistance | Generally High | Grade Dependent | Grade Dependent |
| Compressive Strength | Available in High-Strength Grades | Available in Different Strength Grades | Product Dependent |
| Vapour Permeability | Generally Relatively Low | Grade Dependent | Generally High |
| Fire Behaviour | Combustible Polymer | Combustible Polymer | Many Mineral Wool Products Are Non-Combustible |
| Typical Applications | Roofs, Floors, Foundations | Walls, Roofs, Floors | Walls, Roofs, Fire and Acoustic Systems |
The materials are not interchangeable without reviewing thermal, structural, moisture and fire-performance requirements.
Depending on the manufacturer and market, XPS products may be evaluated using standards such as:
| Standard | Description |
|---|---|
| ASTM C578 | Rigid cellular polystyrene thermal insulation specification |
| ASTM C518 | Steady-state thermal transmission properties |
| ASTM D1621 | Compressive properties of rigid cellular plastics |
| ASTM C272 | Water absorption of core materials for sandwich constructions |
| ASTM D2126 | Response of rigid cellular plastics to thermal and humid aging |
| EN 13164 | Factory-made XPS thermal insulation products for buildings |
| EN 826 | Compression behaviour of thermal insulation products |
| EN 12087 | Long-term water absorption by immersion |
Testing requirements and declared performance values depend on the selected product and applicable regional specification.
Before specifying XPS insulation, engineers and procurement teams should evaluate:
Thermal performance: Required insulation thickness, declared conductivity and target U-value.
Compressive loading: Short-term strength and long-term compressive creep under expected loads.
Moisture exposure: Water absorption characteristics and the drainage arrangement.
Fire safety: Required reaction-to-fire classification and compatibility with the complete building assembly.
Installation environment: Temperature, substrate condition, adhesive compatibility and mechanical protection.
Board geometry: Dimensions, thickness tolerances and edge configuration.
Project compliance: Approved technical data sheets, test reports and applicable building regulations.
XPS insulation is generally supplied as rigid boards, packed in manufacturer-standard bundles or protective wrapping.
The existing product listing specifies:
Board size: 600 × 1000 mm.
Nominal board area: 0.60 m².
Listed density: 32–35 kg/m³.
Supply unit: Sheet.
Other board thicknesses, dimensions, densities and packaging quantities may be sourced according to manufacturer availability and project requirements.
Buyers should confirm the thickness and number of boards per pack before comparing prices.
Yaseen Construction Products can review XPS insulation sourcing requirements against recognised product references, including:
DuPont STYROFOAM and ROOFMATE product ranges.
E-Foam.
E-Roof, E-Wall and E-Floor insulation references.
Other approved XPS insulation manufacturers.
Equivalent products should be evaluated against thermal conductivity, compressive strength, water absorption, board dimensions, fire classification and relevant standards.
Brand references are provided for product identification and comparison. They do not imply manufacturer affiliation, stock availability or automatic technical equivalence.
XPS insulation prices depend on thickness, density, compressive-strength grade, thermal performance, board dimensions, manufacturer and order quantity.
For accurate quotations, buyers should provide:
Required XPS board thickness.
Density or specified compressive-strength grade.
Thermal conductivity or thermal resistance requirement.
Board dimensions and total coverage area.
Application, such as roof, wall, floor or foundation.
Approved brand or technical specification.
Delivery destination and required quantity.
For project procurement, comparing price per square metre at the same thickness and performance grade is generally more useful than comparing sheet prices alone.
Yaseen Construction Products supplies and exports Extruded Polystyrene (XPS) insulation boards for commercial, residential, industrial and infrastructure projects across the UAE, Saudi Arabia, Qatar, Oman, Kuwait and African countries, including Nigeria, Kenya, Ghana, Tanzania, Uganda, Ethiopia, South Africa, Egypt, Morocco, Rwanda, Zambia, Mozambique and Senegal.
We support contractors, insulation specialists, developers and procurement teams with specification-based sourcing, bulk quotations, technical documentation and international shipment arrangements. Product availability, pricing and delivery schedules depend on the required specifications, order quantity and destination.
Low Thermal Conductivity: Reduces heat transfer through properly insulated building assemblies.
Moisture Resistance: Predominantly closed-cell structure limits water absorption compared with many open-cell insulation materials.
Compressive Strength: Available in grades designed to withstand loads in roofs, floors and foundations.
Dimensional Stability: Suitable grades maintain dimensional performance within specified service conditions.
Lightweight Construction: Rigid foam boards are relatively easy to transport, handle and install.
Uniform Board Structure: Extrusion produces a consistent foam structure that supports predictable insulation performance.
Below-Grade Suitability: Selected grades can be used in foundation and perimeter insulation systems with appropriate protection.
Flexible Board Selection: Available in different thicknesses, strengths and edge profiles for project-specific applications.
Long-Term Insulation Performance: Declared aged thermal properties allow designers to assess performance over the intended service life.
Installation Efficiency: Boards can be cut and fitted around compatible building details using approved methods.
Inverted Roof Insulation: Thermal insulation installed above waterproofing membranes in approved protected roof systems.
Conventional Flat Roofs: Insulation within compatible roof assemblies.
Pitched Roofs: Thermal insulation in appropriately designed pitched-roof systems.
External Wall Insulation: Selected XPS grades used in approved facade and external insulation systems.
Cavity Walls: Insulation between wall layers where permitted by the building design.
Ground-Bearing Floors: Insulation beneath or within floor assemblies subject to compressive-load requirements.
Foundation and Basement Walls: Perimeter insulation in below-grade construction.
Industrial Flooring: High-compressive-strength grades for selected loaded floor assemblies.
Cold Storage Facilities: Thermal insulation in approved temperature-controlled building systems.
Parking Decks and Podiums: Insulation in suitable roof or deck assemblies, subject to structural loading and protection.
Precast Building Elements: Thermal insulation within compatible composite or sandwich-panel systems.
Commercial and Residential Buildings: Building-envelope insulation designed to reduce unwanted heat transfer.
Extruded Polystyrene is a rigid, closed-cell foam insulation manufactured from polystyrene resin. It is used to reduce heat transfer through roofs, walls, floors and foundations. XPS boards are selected according to thermal conductivity, thickness, compressive strength, moisture exposure and building-system requirements.
XPS is produced through extrusion, while Expanded Polystyrene (EPS) is manufactured by expanding and moulding polystyrene beads. XPS generally offers relatively low water absorption and is available in high-compressive-strength grades. However, actual thermal and mechanical performance must be compared using specific product data rather than material names alone.
The required thickness depends on the target roof U-value, declared thermal conductivity, climate, roof assembly and applicable energy regulations. An insulation designer should calculate the required thickness using the complete roof construction rather than selecting a standard thickness without assessment.
Yes. Suitable XPS insulation boards are commonly used in inverted roof systems, where the insulation is installed above the waterproofing membrane. The system must address water drainage, ballast, wind uplift, moisture exposure and thermal performance.
Density measures the mass of the foam per unit volume, normally expressed in kg/m³. Compressive strength measures resistance to compressive loading, normally expressed in kPa. Although density can influence strength, it should not be used as a substitute for verified compressive-strength data.
XPS has a predominantly closed-cell structure and generally exhibits low water absorption. However, XPS boards are not a replacement for a properly designed waterproofing membrane. Joints, penetrations and the complete construction assembly must be addressed separately.
XPS is a combustible polymer insulation material. Fire performance depends on the product formulation, protective layers and complete building assembly. The relevant fire classification and local building-code requirements must be verified before specifying XPS.
The current Yaseen product listing specifies a 600 × 1000 mm board with a listed density of 32–35 kg/m³. Thickness, edge profile and alternative dimensions should be confirmed for the selected grade before ordering.
Divide the total insulation area by the coverage of one board, then account for cutting losses and installation details. A 600 × 1000 mm board covers 0.60 m², so 100 m² requires approximately 167 boards before allowing for wastage.
XPS can be installed in compatible protected-membrane roof systems, but material compatibility and installation methods must follow the approved system design. Adhesives, solvents, drainage layers and protective materials should be checked for compatibility with both the insulation and waterproofing membrane.
The main pricing factors include board thickness, density, compressive-strength grade, thermal conductivity, dimensions, manufacturer, order quantity and delivery destination. Buyers should compare equivalent technical grades and cost per square metre.
Yaseen Construction Products handles bulk XPS insulation board supply and export enquiries across the UAE, Saudi Arabia, Qatar, Oman, Kuwait and African countries, including Nigeria, Kenya, Ghana, Tanzania, Uganda, Ethiopia, South Africa, Egypt, Morocco, Rwanda, Zambia, Mozambique and Senegal.
We support contractors, insulation specialists, developers and procurement teams with specification-based sourcing, bulk quotations and shipment arrangements according to order requirements.
Trusted supplier and exporter of building construction products in UAE, Saudi, Qatar, Oman & African Countries.
Still confused?
We are happy to help on our expertise with no conditions.