Images shown are for reference only. Product specifications, packaging, and appearance may differ based on brand or batch.
14.00 USD
Yaseen Construction Products supplies Acrylic Cementitious Waterproofing Coatings for concrete structures, basements, bathrooms, balconies, water-retaining structures and other approved construction waterproofing applications.
Acrylic cementitious coatings combine cement-based materials with acrylic polymer modification to form a protective waterproofing layer. Available grades include flexible two-component systems and other polymer-modified cementitious formulations designed for specific substrate, movement and water-pressure conditions.
Acrylic Cementitious Waterproofing Coating is a polymer-modified cement-based material used to form a protective waterproofing layer over suitable concrete and masonry substrates.
These coatings combine cementitious binders with acrylic polymer components to provide adhesion, water resistance and specified flexibility. Depending on the formulation, they may be supplied as two-component systems containing a cement-based powder and acrylic polymer liquid, or as other manufacturer-approved formulations.
Acrylic cementitious coatings are used in selected basement waterproofing systems, bathrooms, balconies, water tanks, swimming pools and concrete structures.
Yaseen Construction Products sources acrylic cementitious waterproofing coatings for waterproofing contractors, civil engineering companies, infrastructure projects, commercial developments and bulk construction procurement.
Acrylic Cementitious Waterproofing Coating is a cement-based waterproofing material modified with acrylic polymer.
A typical two-component system contains:
Cementitious powder.
Graded mineral fillers.
Performance additives.
Acrylic polymer liquid.
Manufacturer-specified modifiers.
The powder and liquid components are mixed in the approved ratio before application.
The coating develops its properties through cement hydration and polymer film formation.
The finished waterproofing layer’s performance depends on formulation, mixing, thickness, curing and substrate conditions.
The coating is applied to a prepared concrete or masonry surface.
During curing, cement hydration and polymer film formation produce a protective layer.
Suitable formulations may provide:
Resistance to water penetration.
Adhesion to cementitious substrates.
Flexibility.
Crack-bridging performance.
Compatibility with approved tile finishes.
Protection of concrete and masonry surfaces.
The coating must be applied at the specified thickness and properly cured.
A flexible cementitious coating does not replace structural crack repair or movement-joint detailing.
Two-component systems contain a cementitious powder and polymer liquid.
Selected grades are formulated to accommodate specified substrate movement.
They are commonly used in approved bathrooms, balconies, water tanks and concrete waterproofing systems.
Some cementitious waterproofing coatings provide limited flexibility.
They may be suitable for stable concrete or masonry substrates where the specification does not require significant crack bridging.
A rigid cementitious coating should not be substituted for a flexible system without approval.
Selected formulations contain reinforcing fibres.
These may improve specified mechanical or application properties.
Fibre reinforcement alone does not establish crack-bridging capability.
Brush-applied grades are designed for controlled application over prepared surfaces.
The specified number of coats and thickness must be maintained.
Certain formulations are suitable for approved spray equipment.
Equipment selection, mixing, application thickness and curing must follow manufacturer instructions.
Selected grades are approved for water-retaining structures.
Potable water applications require specific suitability documentation for contact with drinking water.
Not every acrylic cementitious coating is suitable for potable water tanks.
| Parameter | Specification / Selection Criteria |
|---|---|
| Product | Acrylic Cementitious Waterproofing Coating |
| Material Type | Polymer-Modified Cementitious Coating |
| Polymer Modifier | Acrylic Polymer or Approved Formulation |
| Components | Commonly Two-Component |
| Powder Composition | Cement, Fillers and Additives |
| Liquid Composition | Acrylic Polymer Dispersion |
| Mixing Ratio | Manufacturer Specified |
| Mixed Density | Manufacturer Declared |
| Pot Life | Manufacturer Specified |
| Application Thickness | Manufacturer Specified |
| Number of Coats | Manufacturer Specified |
| Coverage | Manufacturer Declared |
| Initial Set / Drying Time | Manufacturer Specified |
| Recoat Interval | Manufacturer Specified |
| Full Cure Time | Manufacturer Specified |
| Adhesion Strength | Manufacturer Declared |
| Tensile Strength | Where Tested |
| Elongation | Where Tested |
| Crack-Bridging Performance | Where Tested |
| Water Impermeability | Manufacturer Declared |
| Positive Water Pressure Resistance | Where Tested |
| Negative Water Pressure Resistance | Where Tested |
| Water Vapour Permeability | Where Relevant |
| Chloride Ion Permeability | Where Relevant |
| Application Temperature | Manufacturer Specified |
| Substrate Moisture Condition | Manufacturer Specified |
| Packaging | Powder Bags and Polymer Liquid Containers |
Actual values must be confirmed using the selected manufacturer’s technical data sheet and test reports.
Acrylic cementitious coatings and acrylic waterproofing coatings are different materials.
| Property | Acrylic Cementitious Coating | Acrylic Waterproofing Coating |
|---|---|---|
| Main Composition | Cementitious Binder with Acrylic Polymer | Acrylic Polymer Binder |
| Common Packaging | Powder and Liquid Components | Liquid |
| Curing | Cement Hydration and Polymer Film Formation | Commonly Water Evaporation and Film Formation |
| Typical Substrates | Concrete and Masonry | Approved Concrete, Roof and Exterior Surfaces |
| Common Applications | Wet Areas, Tanks and Structural Waterproofing | Roofs and Exterior Waterproofing |
| Crack Bridging | Flexible Grades Available | Elastomeric Grades Available |
| UV Exposure | System Dependent | Exposed Grades Available |
| Tile Compatibility | Suitable Grades Available | Product Dependent |
Selection depends on the approved application and performance requirements.
Polyurethane coatings form polymer membranes through their specific curing chemistry.
Acrylic cementitious coatings combine cement-based binders with polymer modification.
Important differences include:
Substrate moisture tolerance.
Application thickness.
Curing.
Flexibility.
Crack-bridging performance.
UV exposure.
Water-pressure resistance.
Compatibility with tile finishes.
Neither system should be substituted without reviewing the project specification.
Crystalline waterproofing materials use cementitious chemistry designed to form or promote water-blocking crystalline products within suitable concrete.
Acrylic cementitious coatings form a protective layer over the substrate.
These systems differ in mechanism, substrate requirements and performance.
They should not be treated as direct equivalents.
Bituminous waterproofing systems use bitumen-based materials.
Acrylic cementitious coatings use cementitious binders modified with polymer.
Bituminous systems are commonly used in approved below-ground and roofing applications.
Acrylic cementitious coatings are frequently specified for concrete, masonry and wet-area waterproofing.
The correct choice depends on exposure, movement, finishes and water-pressure conditions.
Flexible acrylic cementitious coatings are commonly used in approved bathroom waterproofing systems.
Critical areas include:
Shower floors.
Bathroom floors.
Wall-to-floor junctions.
Pipe penetrations.
Drainage outlets.
Shower walls.
Door thresholds.
The system must be compatible with the screed, tile adhesive and subsequent finishes.
Selected flexible cementitious coatings may be used beneath tile finishes on balconies.
The waterproofing design must address:
Surface falls.
Drainage.
Movement joints.
Door thresholds.
Parapet junctions.
Thermal movement.
Tile adhesive compatibility.
Suitable acrylic cementitious coatings may be used in approved basement waterproofing systems.
Selection must consider:
Groundwater conditions.
Positive water pressure.
Negative water pressure.
Concrete condition.
Structural joints.
Cracks.
Required coating thickness.
Not every acrylic cementitious coating is approved for negative-side waterproofing.
Selected products may be used for waterproofing water-retaining concrete structures.
Important requirements include:
Water-pressure resistance.
Crack-bridging performance.
Curing.
Water contact suitability.
Cleaning requirements.
Tank commissioning.
For potable water tanks, verify compliance with the applicable drinking-water contact requirements.
Suitable grades may be used beneath approved swimming pool finishes.
Swimming pool waterproofing must consider:
Water pressure.
Chemical exposure.
Substrate movement.
Tile adhesive compatibility.
Joint detailing.
Continuous immersion.
Only products specifically approved for swimming pool conditions should be used.
Acrylic cementitious coatings may be applied to suitable concrete elements.
Applications may include:
Concrete walls.
Slabs.
Water-retaining structures.
Wet-area substrates.
Selected below-ground surfaces.
The coating must be compatible with the actual exposure.
Suitable products may be applied to prepared masonry surfaces.
Uneven or highly porous masonry may require:
Surface levelling.
Joint filling.
Repair mortar.
Moisture conditioning.
Additional material consumption.
Selected flexible cementitious waterproofing systems may be used beneath compatible finishes on podium decks.
The design must consider structural movement, loading, drainage and waterproofing continuity.
Positive-side waterproofing is applied to the side directly exposed to water.
Negative-side waterproofing is applied to the opposite side.
Some cementitious waterproofing products are approved for positive-side exposure only.
Others may have tested negative-side water-pressure resistance.
Negative-side suitability must be confirmed for the actual product.
Flexible acrylic cementitious coatings may provide tested crack-bridging performance.
Selection should consider:
Crack width.
Expected movement.
Temperature.
Coating thickness.
Reinforcement.
Crack-bridging classification.
Active structural movement joints require appropriate joint systems.
Some systems require reinforcement at:
Wall-to-floor junctions.
Corners.
Pipe penetrations.
Drainage outlets.
Cracks.
Construction joints.
Other systems may require full-surface reinforcement.
Use only manufacturer-approved fabrics, meshes or detailing accessories.
Before application:
Remove dust and debris.
Remove weak concrete.
Remove oil and contaminants.
Repair cracks and defects.
Fill voids.
Prepare corners.
Check substrate strength.
Confirm surface moisture conditions.
Verify application temperature.
Some cementitious waterproofing systems require the substrate to be pre-dampened.
Others have different moisture requirements.
Follow the manufacturer’s instructions.
Confirm the selected coating, mixing ratio, thickness, number of coats and intended exposure.
Clean and repair the concrete or masonry.
Prepare the substrate moisture condition according to the manufacturer’s instructions.
Combine powder and polymer liquid in the specified ratio.
Use suitable mechanical mixing equipment where required.
Do not add extra water unless expressly permitted.
Apply using the approved brush, roller, trowel or spray method.
Maintain the specified thickness.
Embed compatible reinforcement at specified junctions and penetrations.
Follow the specified recoat interval.
Where required, apply subsequent coats in the approved direction to improve coverage.
Protect the material from premature drying, rain, traffic and other unsuitable exposure.
Check:
Coating continuity.
Thickness.
Pinholes.
Cracks.
Debonding.
Joint detailing.
Curing.
Install compatible tile adhesives, screeds or other finishes after the specified curing period.
Water-retaining structures must be commissioned according to the approved procedure.
Possible causes include:
Excessive application thickness.
Rapid drying.
Substrate movement.
Incorrect mixing.
Inadequate curing.
Possible causes include:
Weak substrate.
Dust or contamination.
Incorrect surface moisture.
Poor preparation.
Possible causes include:
Porous substrates.
Inadequate coverage.
Poor application technique.
Possible causes include:
Incorrect mixing ratio.
Unsuitable temperature.
Premature water exposure.
Incorrect curing conditions.
Possible causes include:
Missing reinforcement.
Incorrect joint detailing.
Movement beyond the coating’s capability.
| Standard | Application |
|---|---|
| EN 14891 | Liquid-applied water-impermeable products beneath ceramic tiling |
| EN 1504-2 | Surface protection systems for concrete, where applicable |
| EN 1062-7 | Determination of crack-bridging properties, where applicable |
| EN 1542 | Pull-off adhesion strength |
| EN 1062-3 | Liquid water permeability, where applicable |
| EN ISO 7783 | Water vapour transmission properties, where applicable |
| ASTM C1583/C1583M | Tensile strength of concrete surfaces and bond strength of repairs or overlays by direct tension |
| ASTM D4541 | Pull-off strength of coatings, where applicable |
Standards must be matched to the actual product category and application. Compliance must be verified through manufacturer documentation.
Buyers should confirm:
Bathroom, basement, tank or other application.
Flexible or rigid grade.
Two-component or other formulation.
Positive-side or negative-side exposure.
Hydrostatic pressure requirements.
Crack-bridging performance.
Adhesion.
Required thickness.
Number of coats.
Substrate moisture requirements.
Pot life.
Curing time.
Tile compatibility.
Continuous immersion suitability.
Potable water contact approval where required.
Packaging.
Project quantity.
Acrylic cementitious coatings are commonly supplied as powder and liquid component kits.
Consumption is usually expressed in kg/m² at the specified thickness.
Theoretical quantity (kg) = Area (m²) × Manufacturer’s Consumption (kg/m²)
For example, assume a selected coating requires 3.0 kg/m² for the specified complete waterproofing system.
For a 200 m² project:
Theoretical quantity: 600 kg.
With an illustrative 10% allowance: 660 kg.
If the approved kit contains 30 kg of combined material, the illustrative requirement is 22 kits.
Actual consumption depends on the selected product, coating thickness, substrate condition and application losses.
Yaseen Construction Products can review sourcing enquiries against relevant polymer-modified cementitious waterproofing systems from manufacturers such as:
Sika SikaTop and Sikalastic cementitious waterproofing ranges.
Fosroc Brushbond waterproofing systems.
Mapei Mapelastic waterproofing systems.
Other approved cementitious waterproofing manufacturers.
Brand references are for technical comparison and product identification only. They do not imply manufacturer affiliation, guaranteed availability or direct equivalence.
Equivalent products must be compared using flexibility, crack bridging, adhesion, water-pressure resistance, application thickness and intended exposure.
Pricing depends on:
Formulation.
Flexible or rigid grade.
Polymer content.
Performance requirements.
Packaging.
Manufacturer.
Order quantity.
Delivery destination.
For accurate comparisons, evaluate the complete installed waterproofing cost per square metre at the required thickness.
For a specification-based quotation, provide:
Project location.
Bathroom, basement, water tank or other application.
Substrate type.
Positive-side or negative-side waterproofing.
Required water-pressure resistance.
Crack-bridging requirements.
Required thickness.
Applicable technical standard.
Surface area.
Reinforcement requirements.
Potable water approval where relevant.
Required quantity.
Delivery destination.
Delivery schedule.
Yaseen Construction Products supplies and exports acrylic cementitious waterproofing coatings for bathrooms, basements, water tanks, balconies, swimming pools and approved concrete waterproofing systems across the UAE, Saudi Arabia, Qatar, Oman, Kuwait and African countries, including Nigeria, Kenya, Ghana, Tanzania, Uganda, Ethiopia, South Africa, Egypt, Morocco, Rwanda, Zambia, Mozambique and Senegal.
We support waterproofing contractors, civil engineering companies, infrastructure contractors, property developers, water-retaining structure specialists and procurement teams with specification-based sourcing, bulk quotations and international shipment arrangements.
Product availability, pricing and delivery schedules depend on formulation, packaging, quantity and destination.
Concrete Compatibility: Suitable grades bond to properly prepared concrete and cementitious substrates.
Polymer Modification: Acrylic components improve selected adhesion and flexibility properties.
Flexible Grades: Available with tested crack-bridging performance.
Wet-Area Waterproofing: Suitable systems are used beneath bathroom and balcony finishes.
Water-Retaining Structures: Approved grades can be used in tanks and swimming pools.
Positive-Side Protection: Suitable formulations resist water penetration from the exposed side.
Negative-Side Options: Selected products are tested for negative-side water pressure.
Tile Compatibility: Suitable grades can be covered with approved tile adhesive systems.
Brush Application: Many products can be applied using conventional waterproofing tools.
Joint Reinforcement: Compatible systems support reinforced junction and penetration details.
Specification-Based Thickness: Consumption can be calculated from the required coating thickness.
Bulk Project Supply: Suitable for commercial, residential and infrastructure waterproofing projects.
Bathrooms: Waterproofing beneath approved floor and wall finishes.
Shower Areas: Protection around floors, drains and wall junctions.
Balconies: Waterproofing beneath compatible tile systems.
Basement Walls: Approved positive-side or negative-side waterproofing.
Water Tanks: Waterproofing of suitable concrete water-retaining structures.
Swimming Pools: Approved waterproofing beneath compatible finishes.
Concrete Slabs: Protection of specified structural concrete surfaces.
Masonry Walls: Waterproofing of prepared blockwork and brickwork.
Podium Decks: Selected waterproofing systems beneath protective finishes.
Utility Rooms: Waterproofing of wet-service areas.
Commercial Buildings: Concrete and wet-area waterproofing.
Infrastructure Structures: Application-specific cementitious waterproofing systems.
Acrylic Cementitious Waterproofing Coating is a cement-based waterproofing material modified with acrylic polymer. It is commonly supplied as a two-component system containing cementitious powder and polymer liquid, although other formulations are available.
It is used for waterproofing bathrooms, balconies, basements, water tanks, swimming pools and approved concrete or masonry structures. The correct grade depends on water pressure, movement and exposure.
Acrylic coating generally forms a polymer film, while acrylic cementitious coating combines cementitious binders with polymer modification. Their curing, substrate compatibility, flexibility and application requirements differ.
Flexible grades are available and may provide tested crack-bridging performance. However, not every cementitious waterproofing coating is flexible. The required performance must be verified from manufacturer data.
Yes. Suitable products are commonly used beneath approved bathroom floor and wall finishes. Junctions, drains and penetrations require proper detailing.
Yes, if the selected product is approved for water-retaining structures. Potable water tanks require additional verification of suitability for drinking-water contact.
Selected products are suitable for swimming pool waterproofing. The system must be approved for continuous immersion, water pressure, chemical exposure and compatibility with the specified finishes.
Some products are approved for negative-side water pressure, while others are intended only for positive-side applications. The selected coating must have appropriate performance documentation.
Primer requirements depend on the product and substrate. Some systems require pre-dampening of concrete rather than a separate primer. Follow the manufacturer’s application instructions.
Many systems require multiple coats to achieve the specified thickness. The number of coats, application rate and curing intervals must follow the manufacturer’s technical data sheet.
Consumption depends on the product and specified thickness. For example, if a selected coating requires 3.0 kg/m² for the complete system, a 200 m² area requires 600 kg before application losses. Actual consumption must follow manufacturer data.
Yaseen Construction Products supplies and exports acrylic cementitious waterproofing coatings for bathrooms, basements, water tanks, swimming pools, balconies and concrete structures across the UAE, Saudi Arabia, Qatar, Oman, Kuwait and African countries, including Nigeria, Kenya, Ghana, Tanzania, Uganda, Ethiopia, South Africa, Egypt, Morocco, Rwanda, Zambia, Mozambique and Senegal.
We assist waterproofing contractors, civil engineering companies, infrastructure contractors, property developers and procurement teams with specification matching, bulk quotations and international shipment arrangements.
Trusted supplier and exporter of building construction products in UAE, Saudi, Qatar, Oman & African Countries.
Still confused?
We are happy to help on our expertise with no conditions.