Images shown are for reference only. Product specifications, packaging, and appearance may differ based on brand or batch.
30.00 USD
Yaseen Construction Products supplies APP Waterproofing Membranes for flat roofs, podium slabs, basements, foundations, retaining walls and other approved building waterproofing applications.
APP membranes use atactic polypropylene-modified bitumen to provide waterproofing performance, dimensional stability and resistance to elevated temperatures. Available grades include polyester-reinforced, fiberglass-reinforced, mineral-finished and film-finished membranes for different installation and exposure requirements.
APP Waterproofing Membrane is a factory-manufactured bituminous sheet used to protect suitable building structures against water penetration.
APP stands for atactic polypropylene, a plastomeric polymer modifier blended with bitumen to produce waterproofing membranes with specified temperature resistance, dimensional characteristics and mechanical performance.
APP modified bitumen membranes are commonly used in roofing systems, protected podium slabs and approved below-ground waterproofing applications.
They are manufactured with different reinforcement carriers, thicknesses and surface finishes to meet project-specific requirements.
Yaseen Construction Products sources APP waterproofing membranes for roofing contractors, waterproofing specialists, civil engineering companies, property developers and infrastructure procurement teams.
APP Waterproofing Membrane is a flexible waterproofing sheet manufactured using bitumen modified with atactic polypropylene or related plastomeric compounds.
A typical APP membrane may contain:
APP-modified bituminous compound.
Polyester, fiberglass or composite reinforcement.
Upper protective surface.
Lower application surface.
Manufacturer-specific additives.
The membrane is supplied in rolls and installed using the method approved for the selected product.
APP modification changes the physical behaviour of bitumen.
Depending on formulation, APP membranes can offer:
Resistance to flow at elevated temperatures.
Dimensional stability.
Mechanical reinforcement.
Resistance to water penetration.
Weather resistance when provided with an approved exposed surface finish.
Actual performance depends on polymer content, reinforcement, thickness and membrane construction.
APP modification alone does not establish UV resistance, watertightness under every exposure condition or suitability for a particular structure.
Polyester-reinforced APP membranes contain a polyester carrier.
They are commonly selected for roofing and other waterproofing systems requiring specified tensile and elongation properties.
Their suitability depends on the finished membrane’s declared performance.
Fiberglass-reinforced APP membranes use glass fibre carriers.
Selected grades provide dimensional stability and mechanical reinforcement.
Fiberglass and polyester reinforcement should not be treated as directly interchangeable.
Composite membranes use combined or specialised reinforcement constructions.
These may be selected for project-specific mechanical and dimensional requirements.
Torch applied APP membranes use controlled heat to bond the bituminous sheet to a prepared substrate or compatible underlying layer.
Torch installation requires trained personnel and appropriate fire safety precautions.
Mineral-finished APP membranes contain mineral granules on the upper surface.
Suitable grades are used as exposed roofing cap sheets where approved by the manufacturer.
Film-finished APP membranes are commonly used in protected waterproofing systems or as base layers in multi-ply assemblies.
They should not automatically be used as exposed roofing membranes.
Selected APP membranes have sanded surfaces for specified installation or bonding requirements.
The surface finish must match the intended waterproofing assembly.
| Parameter | Specification / Selection Criteria |
|---|---|
| Product | APP Waterproofing Membrane |
| Waterproofing Compound | APP Modified Bitumen |
| Polymer Type | Plastomeric Modifier |
| Reinforcement | Polyester, Fiberglass or Composite |
| Thickness | Manufacturer Specified |
| Roll Width | Manufacturer Specified |
| Roll Length | Manufacturer Specified |
| Mass per Unit Area | Manufacturer Declared |
| Upper Surface | Mineral, Film, Sand or Approved Finish |
| Lower Surface | Manufacturer Specified |
| Tensile Strength | Manufacturer Declared |
| Elongation | Manufacturer Declared |
| Tear Resistance | Manufacturer Declared |
| Watertightness | Manufacturer Declared |
| Low-Temperature Flexibility | Manufacturer Declared |
| Flow Resistance at Elevated Temperature | Manufacturer Declared |
| Dimensional Stability | Manufacturer Declared |
| Joint Peel Resistance | Where Required |
| Joint Shear Resistance | Where Required |
| Impact Resistance | Where Required |
| Static Loading Resistance | Where Required |
| Installation Method | Manufacturer Approved |
| Packaging | Rolls |
Actual specifications must be verified using the selected manufacturer’s technical data sheet and test reports.
APP and SBS are both polymer-modified bituminous waterproofing membranes.
Their main difference is the type of polymer used.
| Property | APP Membrane | SBS Membrane |
|---|---|---|
| Polymer Modifier | Atactic Polypropylene | Styrene-Butadiene-Styrene |
| Polymer Behaviour | Plastomeric | Elastomeric |
| Elevated-Temperature Performance | Often a Selection Advantage | Product Dependent |
| Low-Temperature Flexibility | Product Dependent | Often a Selection Advantage |
| Elastic Recovery | Formulation Dependent | Commonly Associated with SBS Modification |
| Reinforcement | Polyester, Fiberglass or Composite | Polyester, Fiberglass or Composite |
| Surface Finish | Mineral, Film or Sand | Mineral, Film or Other Approved Finish |
| Installation | Commonly Torch Applied | Torch Applied, Self Adhesive or Other Approved Method |
| Typical Applications | Roofing and Approved Below-Ground Waterproofing | Roofing and Approved Below-Ground Waterproofing |
The correct membrane should be selected using actual test results rather than polymer type alone.
APP describes the polymer modification of the bituminous compound.
Self adhesive describes how a membrane bonds to a substrate.
Conventional APP membranes are commonly torch applied, while self adhesive membranes use an integrated adhesive layer.
The installation method must be confirmed for the selected product.
APP membranes are prefabricated sheets with defined thickness and roll dimensions.
Liquid waterproofing materials form a continuous coating after application and curing.
APP membranes require correctly formed joints and laps.
Liquid systems require controlled application thickness, curing and compatible reinforcement where specified.
The correct system depends on exposure, substrate geometry and project requirements.
APP membranes are widely used in approved flat and low-slope roof waterproofing systems.
Applications may include:
Reinforced concrete roof decks.
Protected roof assemblies.
Exposed roofs with approved mineral-finished membranes.
Roof upstands.
Parapet junctions.
Drainage outlets.
Equipment plinths.
The complete roof design must address drainage, falls, movement, insulation compatibility and termination details.
APP modified bitumen membranes are frequently considered for roofing in hot climates because suitable formulations can provide resistance to flow at elevated temperatures.
However, suitability for hot weather must be assessed using:
Heat resistance test results.
Surface finish.
UV exposure requirements.
Roof slope.
Substrate temperature.
Dimensional stability.
Installation conditions.
A membrane should not be selected solely because it contains APP.
Selected APP membranes may be used in approved basement waterproofing systems.
Important factors include:
Groundwater conditions.
Hydrostatic pressure.
Membrane watertightness.
Joint performance.
Structural movement.
Substrate preparation.
Mechanical protection.
A roofing-grade APP membrane should not automatically be used for below-ground waterproofing.
Suitable APP membranes may be specified for foundation waterproofing.
The design must account for:
Ground moisture.
Water pressure.
Foundation geometry.
Construction joints.
Membrane continuity.
Protection during backfilling.
APP membranes may be used on compatible retaining wall surfaces.
The membrane should be installed according to the approved waterproofing system, with suitable protection before backfilling.
A drainage system may also be required.
APP membranes can be used in approved podium waterproofing systems.
Selection must consider:
Structural movement.
Drainage.
Overburden.
Mechanical loading.
Membrane protection.
Junction detailing.
APP waterproofing membranes may be specified for:
Shopping centres.
Office buildings.
Hotels.
Industrial facilities.
Institutional buildings.
Residential towers.
The application depends on the actual membrane grade and waterproofing specification.
Polyester and fiberglass reinforcement differ in mechanical characteristics.
Polyester reinforcement may provide higher elongation in suitable membrane constructions.
Fiberglass reinforcement may offer dimensional stability in specified products.
The finished membrane’s tested tensile strength, elongation and dimensional stability should guide selection.
| Property | Mineral-Finished APP | Film-Finished APP |
|---|---|---|
| Surface | Mineral Granules | Film or Other Specified Finish |
| Typical Position | Approved Exposed Cap Sheet | Base Layer or Protected System |
| UV Exposure | Suitable Grades Designed for Exposure | Not Automatically Suitable |
| Surface Protection | Mineral Finish | Requires Approved System Protection Where Specified |
| Common Use | Exposed Roof Waterproofing | Multi-Ply and Protected Waterproofing |
APP systems may use one or more membrane layers.
A single-layer system requires a membrane specifically approved for that application.
A two-layer system may include:
Base membrane.
Cap membrane.
Approved primer.
Joint and termination accessories.
The specified number of layers should not be reduced without design approval.
Before APP membrane installation:
Remove dust and debris.
Remove loose concrete.
Repair surface defects.
Remove oil and contaminants.
Prepare corners and fillets.
Check substrate moisture.
Apply approved primer.
Allow primer to dry as specified.
Confirm suitable weather conditions.
Confirm membrane thickness, reinforcement, primer, laps and surface finish.
Clean and repair the surface.
Apply the compatible bituminous primer where required.
Unroll, align and cut the membrane before bonding.
Use approved torch equipment to heat the lower bituminous surface and bond the membrane.
Avoid overheating and damage to the reinforcement.
Form the specified overlaps using the manufacturer’s approved welding method.
Complete corners, upstands, drains, penetrations and terminations.
Check bonding, laps, continuity and visible defects.
Provide the required protective layer for protected or below-ground systems.
Torch application must be carried out by trained personnel with suitable fire precautions.
Possible causes include:
Insufficient heating.
Contaminated surfaces.
Incorrect overlap.
Poor workmanship.
Possible causes include:
Trapped moisture.
Inadequate substrate preparation.
Poor bonding.
Excessive heat may damage the membrane compound or reinforcement.
Sharp construction materials and site activities can damage installed membranes.
Using a non-exposed membrane as an exposed cap sheet can reduce durability.
Standing water may expose the system to conditions beyond its approved design.
| Standard | Application |
|---|---|
| EN 13707 | Reinforced bitumen sheets for roof waterproofing |
| EN 13969 | Bitumen damp proof sheets, including basement tanking sheets |
| EN 12311-1 | Tensile properties |
| EN 12310-1 | Tear resistance |
| EN 12316-1 | Joint peel resistance |
| EN 12317-1 | Joint shear resistance |
| EN 1928 | Watertightness |
| EN 1109 | Flexibility at low temperature |
| EN 1110 | Flow resistance at elevated temperature |
| EN 12730 | Resistance to static loading |
| EN 12691 | Resistance to impact |
The applicable standard depends on the intended application. Product compliance must be verified through manufacturer documentation.
Buyers should confirm:
Roofing or below-ground application.
Exposed or protected system.
Required thickness.
Polyester or fiberglass reinforcement.
Mineral or film finish.
Heat resistance.
Low-temperature flexibility.
Tensile strength.
Elongation.
Watertightness.
Joint performance.
Single-layer or multi-layer system.
Installation method.
Primer compatibility.
Roll dimensions.
Required quantity.
APP membranes are commonly supplied in rolls.
Quantity depends on:
Roof or waterproofing area.
Roll width.
Roll length.
Side laps.
End laps.
Upstands.
Penetrations.
Cutting losses.
Number of membrane layers.
Theoretical roll quantity = Total required membrane area ÷ Effective coverage per roll
For example, a 750 m² roof using membrane rolls with an assumed effective coverage of 8.5 m² requires approximately 89 rolls for one layer before additional detailing and wastage.
For multi-layer systems, calculate each layer separately.
Yaseen Construction Products can review sourcing enquiries against relevant APP-modified waterproofing membrane ranges from manufacturers such as:
Sika APP modified bituminous waterproofing membranes.
Soprema APP modified bitumen membrane systems.
Other approved APP waterproofing membrane manufacturers.
Brand references are for product identification and technical comparison. They do not imply manufacturer affiliation, guaranteed availability or automatic equivalence.
Equivalent products must be compared using polymer modification, reinforcement, thickness, heat resistance, low-temperature flexibility, watertightness and intended application.
Pricing depends on:
Membrane thickness.
Reinforcement.
Surface finish.
Performance grade.
Manufacturer.
Roll dimensions.
Order quantity.
Delivery destination.
For accurate comparisons, evaluate the complete waterproofing system, including primer, accessories, protection materials and installation requirements.
For a specification-based quotation, provide:
Project location.
Roof or below-ground application.
Required APP membrane thickness.
Reinforcement type.
Surface finish.
Installation method.
Applicable standards.
Quantity in m² or rolls.
Primer and accessory requirements.
Delivery destination.
Required delivery schedule.
Yaseen Construction Products supplies and exports APP waterproofing membranes for roofs, basements, foundations, retaining walls, podium slabs and approved construction waterproofing systems across the UAE, Saudi Arabia, Qatar, Oman, Kuwait and African countries, including Nigeria, Kenya, Ghana, Tanzania, Uganda, Ethiopia, South Africa, Egypt, Morocco, Rwanda, Zambia, Mozambique and Senegal.
We support roofing contractors, waterproofing specialists, civil engineering companies, property developers and infrastructure procurement teams with specification-based sourcing, bulk quotations and international shipment arrangements.
Product availability, pricing and delivery schedules depend on membrane grade, thickness, reinforcement, quantity and destination.
Elevated-Temperature Resistance: Suitable APP formulations offer resistance to flow at specified higher temperatures.
Waterproofing Protection: Forms a water-resistant barrier when installed as an approved system.
Dimensional Stability: Reinforced grades provide specified dimensional performance.
Roofing Applications: Available for exposed and protected roofing systems.
Reinforcement Options: Polyester, fiberglass and composite grades are available.
Surface Finish Options: Mineral, film and sand finishes support different applications.
Mechanical Performance: Reinforced membranes provide defined tensile and tear properties.
Multi-Layer Compatibility: Suitable membranes can form part of approved multi-ply waterproofing systems.
Below-Ground Applications: Selected grades can be used for basement and foundation waterproofing.
Factory-Manufactured Sheets: Controlled membrane construction supports specification-based procurement.
Project Selection: Different thicknesses and grades can be matched to technical requirements.
Bulk Supply: Roll-based packaging supports large roofing and waterproofing projects.
Flat Roofs: Waterproofing of approved flat and low-slope roofing systems.
Exposed Roofs: Mineral-finished APP membranes approved for exterior exposure.
Protected Roofs: Waterproofing beneath compatible protective layers.
Roof Upstands: Waterproofing of parapet and vertical junction details.
Podium Slabs: Approved waterproofing of podium decks.
Basement Walls: Waterproofing of compatible below-ground wall surfaces.
Foundations: Approved foundation waterproofing systems.
Retaining Walls: Waterproofing before mechanical protection and backfilling.
Commercial Buildings: Roof and substructure waterproofing.
Residential Developments: Waterproofing for villas and apartment buildings.
Industrial Buildings: Roofing and selected below-ground applications.
Institutional Buildings: Waterproofing of suitable roof and basement structures.
APP Waterproofing Membrane is a bituminous waterproofing sheet modified with atactic polypropylene. APP modification changes the physical properties of bitumen and can improve resistance to flow at elevated temperatures in suitable formulations.
APP membranes are used in approved flat roof waterproofing, podium slabs, basement walls, foundations, retaining walls and other building waterproofing systems.
APP is a plastomeric modifier, while SBS is an elastomeric modifier. APP membranes are commonly considered for elevated-temperature performance, while SBS membranes are often selected for flexibility and low-temperature performance. Actual suitability depends on the product’s tested properties.
Selected APP membranes can be suitable for hot climates when their heat resistance, dimensional stability, surface finish and installation method meet the project specification.
Yes. APP membranes are commonly used in approved flat and low-slope roofing systems. Proper drainage, surface finish, lap detailing and roof design are required.
Yes. Suitable APP membranes may be used in approved basement waterproofing systems. The selected grade must meet groundwater exposure, watertightness and joint performance requirements.
Many APP membranes are torch applied. Other installation methods may be available for specific products. Always follow the manufacturer’s approved installation procedure.
Mineral-finished APP membranes may be approved for exposed roofing, while film-finished membranes are commonly used in protected systems or as base layers. The correct finish depends on the intended exposure.
Many APP systems require a compatible bituminous primer on prepared substrates. Primer requirements depend on the membrane, substrate and installation method.
Yes. APP membranes may be installed in approved multi-layer waterproofing systems using specified base and cap sheets. The required number of layers must follow the project design.
Quantity depends on area, roll dimensions, laps, upstands and the number of layers. For example, a 750 m² roof using rolls with an assumed effective coverage of 8.5 m² requires approximately 89 rolls for one layer before detailing and waste.
Yaseen Construction Products supplies and exports APP waterproofing membranes for roofs, basements, foundations, retaining walls and podium slabs across the UAE, Saudi Arabia, Qatar, Oman, Kuwait and African countries, including Nigeria, Kenya, Ghana, Tanzania, Uganda, Ethiopia, South Africa, Egypt, Morocco, Rwanda, Zambia, Mozambique and Senegal.
We assist roofing contractors, waterproofing specialists, civil engineering companies, property developers and procurement teams with specification matching, bulk quotations and international shipment arrangements.
Trusted supplier and exporter of building construction products in UAE, Saudi, Qatar, Oman & African Countries.
Still confused?
We are happy to help on our expertise with no conditions.