Images shown are for reference only. Product specifications, packaging, and appearance may differ based on brand or batch.
24.00 USD
Yaseen Construction Products supplies Acrylic Waterproofing Coatings for roofs, terraces, parapet walls, concrete surfaces and other approved building waterproofing applications.
Acrylic waterproofing coatings are commonly water-based, liquid-applied polymer materials that form a continuous protective film after drying and curing. Selected elastomeric grades provide flexibility, crack-bridging performance and weather resistance for exposed and protected waterproofing systems.
Acrylic Waterproofing Coating is a liquid-applied polymer coating used to protect suitable building surfaces against water penetration and weather exposure.
Many acrylic waterproofing products are based on water-dispersed acrylic polymers. After application, water evaporates and the polymer particles form a continuous film. The finished coating’s waterproofing performance depends on its formulation, thickness, adhesion and curing conditions.
Elastomeric acrylic grades are commonly used in approved roof waterproofing systems, terrace protection, parapet walls and selected concrete or masonry applications.
Yaseen Construction Products sources acrylic waterproofing coatings for roofing contractors, waterproofing specialists, civil engineering companies, property developers and bulk construction procurement.
Acrylic Waterproofing Coating is a liquid material containing acrylic polymer binders and other formulation components.
Depending on the product, these may include:
Acrylic polymer dispersion.
Pigments.
Fillers.
Additives.
Reinforcing components.
Preservatives.
Water or another approved carrier.
After application and film formation, suitable waterproofing grades provide a protective barrier against water penetration.
Not every acrylic coating is a waterproofing membrane. Decorative exterior paints, elastomeric wall coatings and roof waterproofing membranes have different performance requirements.
Acrylic waterproofing coating is applied to a prepared substrate in one or more coats.
As the material dries and cures, it develops a continuous polymer film.
A properly designed and installed system may provide:
Resistance to water penetration.
Weather protection.
Flexibility.
Crack-bridging performance in tested grades.
Adhesion to compatible substrates.
UV resistance in suitable formulations.
Protection against surface moisture.
Performance depends on the specified coating thickness and application conditions.
A coating applied below the required dry film thickness may not provide the intended waterproofing protection.
Elastomeric acrylic coatings are formulated to provide flexibility and elongation.
Suitable grades may accommodate specified substrate movement and bridge cracks within their tested limits.
They are commonly selected for exposed roof waterproofing and other approved exterior applications.
Water-based acrylic coatings use water as the principal carrier.
These products generally form a film through water evaporation and polymer coalescence.
Drying conditions, humidity and temperature affect film formation.
Selected acrylic roof coatings are designed for exterior weather exposure.
They may provide:
UV resistance.
Weather protection.
Reflective surface options.
Resistance to normal roof temperature changes.
Actual performance must be verified from the manufacturer’s technical data.
Reflective acrylic roof coatings are formulated with pigments and fillers that provide specified solar reflectance.
White and other reflective finishes may help reduce roof surface temperature under suitable conditions.
Reflectivity, thermal emittance and long-term performance must be verified using product test data.
A reflective coating does not replace building insulation.
Some acrylic coatings contain reinforcing fibres.
These products may be selected for specific coating or detailing requirements.
Fibre content alone does not establish waterproofing or crack-bridging performance.
Certain acrylic coatings are designed primarily for surface protection rather than waterproofing under standing water or hydrostatic pressure.
The product’s intended use must be confirmed before selection.
| Parameter | Specification / Selection Criteria |
|---|---|
| Product | Acrylic Waterproofing Coating |
| Material Type | Acrylic Polymer Coating |
| Base | Commonly Water-Based |
| Physical Form | Liquid |
| Colour | Manufacturer Standard Colours |
| Density | Manufacturer Declared |
| Solids Content | Manufacturer Declared |
| Viscosity | Manufacturer Declared |
| Drying Time | Manufacturer Specified |
| Recoat Interval | Manufacturer Specified |
| Full Cure Time | Manufacturer Specified |
| Recommended Dry Film Thickness | Manufacturer Specified |
| Coverage | Manufacturer Declared |
| Tensile Strength | Where Tested |
| Elongation at Break | Manufacturer Declared |
| Crack-Bridging Performance | Where Tested |
| Adhesion Strength | Manufacturer Declared |
| Watertightness | Manufacturer Declared |
| Water Vapour Permeability | Where Relevant |
| UV Resistance | Where Applicable |
| Solar Reflectance | For Reflective Grades |
| Thermal Emittance | For Reflective Grades |
| Ponding Water Resistance | Where Specifically Approved |
| Application Temperature | Manufacturer Specified |
| Substrate Moisture Requirements | Manufacturer Specified |
| Packaging | Pails or Drums |
Actual values must be verified using the selected manufacturer’s technical data sheet and relevant test documentation.
| Property | Acrylic Waterproofing Coating | Polyurethane Waterproofing Coating |
|---|---|---|
| Main Binder | Acrylic Polymer | Polyurethane Polymer |
| Common Form | Water-Based Liquid | Single- or Two-Component Liquid |
| Film Formation | Commonly Evaporation and Coalescence | Formulation-Specific Chemical Curing |
| Flexibility | Available in Elastomeric Grades | Available in Elastomeric Grades |
| UV Resistance | Available in Exposed Grades | Available in Exposed Grades |
| Crack Bridging | Product Dependent | Product Dependent |
| Ponding Water Resistance | Requires Specific Approval | Requires Specific Approval |
| Typical Applications | Roofs and Exterior Protection | Roofs, Terraces and Specialised Waterproofing |
Neither system is universally superior. Selection depends on the substrate, weather conditions, exposure and required performance.
Acrylic waterproofing coatings and acrylic cementitious coatings are different product categories.
Acrylic waterproofing coatings generally use acrylic polymer binders to form a protective film.
Acrylic cementitious waterproofing coatings combine cementitious materials with polymer modification.
| Selection Factor | Acrylic Coating | Acrylic Cementitious Coating |
|---|---|---|
| Main Composition | Acrylic Polymer | Cementitious Binder with Polymer Modification |
| Product Form | Liquid | Powder and Liquid, or Other Approved Form |
| Common Applications | Exposed Roofs and Exterior Surfaces | Concrete, Masonry and Wet Areas |
| UV Resistance | Grade Dependent | System Dependent |
| Flexibility | Elastomeric Grades Available | Flexible Grades Available |
| Application | Brush, Roller or Spray | Brush, Roller or Approved Method |
| Curing | Polymer Film Formation | Cement Hydration and Polymer Film Formation |
These materials should not be substituted without checking the approved waterproofing design.
Rubberized bitumen emulsion uses bitumen modified with rubber or elastomeric components.
Acrylic waterproofing coating uses acrylic polymer chemistry.
Rubberized bitumen emulsions are commonly used in selected below-ground moisture protection systems.
Acrylic waterproofing coatings are commonly selected for approved exposed roofing and exterior applications.
However, actual suitability depends on the product formulation and exposure.
Acrylic coatings form a continuous liquid-applied membrane across open areas.
Bituminous sheet membranes are prefabricated rolls installed using approved bonding methods.
Acrylic coatings require controlled application thickness and curing.
Sheet membranes require properly formed laps, terminations and junction details.
The correct system depends on substrate geometry, weather exposure, movement and project specification.
Acrylic coatings are commonly used in approved flat and low-slope roof waterproofing systems.
Roof applications should consider:
Roof slope.
Drainage.
Standing water.
UV exposure.
Thermal movement.
Existing substrate condition.
Reinforcement requirements.
Maintenance access.
Not every acrylic coating is suitable for long-term ponding water exposure.
Suitable acrylic waterproofing systems may be used on terraces.
Terrace waterproofing requires attention to:
Surface falls.
Drainage outlets.
Parapet junctions.
Door thresholds.
Cracks.
Movement joints.
Protective finishes.
Foot traffic.
An ordinary acrylic roof coating should not be used as a traffic-bearing surface unless the manufacturer specifically approves that application.
Acrylic coatings may be applied to prepared concrete roof slabs.
Important requirements include:
Adequate concrete curing.
Surface strength.
Surface moisture.
Cleanliness.
Crack treatment.
Primer compatibility.
Coating thickness.
Selected acrylic coatings may be used to protect parapet walls and roof upstands.
Parapet waterproofing requires continuity with the roof membrane and correct treatment of junctions and terminations.
Certain acrylic elastomeric coatings are suitable for exterior wall protection.
However, exterior wall coatings and roof waterproofing membranes may have different performance requirements.
Wall coatings should be selected according to the actual substrate and expected weather exposure.
Some acrylic roof coating systems are approved for metal roofing substrates.
Metal roof applications require consideration of:
Surface preparation.
Corrosion treatment.
Primer compatibility.
Thermal movement.
Fasteners.
Seams.
Existing coatings.
Do not apply an acrylic coating to metal without confirming product compatibility.
Suitable acrylic systems may be used for roof refurbishment.
Before recoating an existing waterproofing surface, confirm:
Existing membrane condition.
Adhesion.
Surface cleanliness.
Moisture.
Compatibility.
Required repairs.
Primer.
Reinforcement.
New coating thickness.
An acrylic coating should not be used to conceal failed or unstable roofing layers.
Reflective acrylic roof coatings may be selected where solar reflectance is part of the roofing specification.
Performance depends on:
Initial solar reflectance.
Aged solar reflectance.
Thermal emittance.
Surface cleanliness.
Roof geometry.
Climate.
Coating durability.
Energy savings should not be claimed without project-specific evidence.
Selected elastomeric acrylic coatings offer tested crack-bridging performance.
The specification should consider:
Crack width.
Expected movement.
Temperature.
Coating thickness.
Reinforcement.
Crack-bridging classification.
Structural cracks and active movement joints require appropriate treatment.
Some acrylic systems require reinforcement at:
Roof corners.
Parapet junctions.
Drainage outlets.
Pipe penetrations.
Cracks.
Changes in substrate.
Other systems may require full-surface reinforcement.
Compatible polyester fabric or other approved reinforcement should be used according to the manufacturer’s instructions.
Before application:
Remove dust and debris.
Remove oil and contaminants.
Remove loose coatings.
Repair surface defects.
Treat cracks and joints.
Check substrate moisture.
Confirm surface strength.
Apply approved primer.
Verify weather conditions.
Confirm coating grade, primer, reinforcement, number of coats and required dry film thickness.
Clean and repair the surface.
Confirm that substrate moisture and weather conditions are suitable.
Use the approved primer where required.
Mix according to the manufacturer’s instructions.
Do not dilute unless expressly permitted.
Apply by brush, roller, spray or another approved method.
Maintain the specified wet film thickness.
Embed compatible reinforcement at junctions and other specified locations.
Allow the required drying interval before subsequent coats.
Verify that the total applied coating meets the specified thickness.
Protect the coating from rain, traffic and other unsuitable exposure until the required curing condition is achieved.
Possible causes include:
Trapped moisture.
Poor substrate preparation.
Incompatible existing coatings.
Excessive coating thickness.
Possible causes include:
Weak substrate.
Dust or contamination.
Incorrect primer.
Poor adhesion.
Possible causes include:
Excessive substrate movement.
Inadequate coating thickness.
Incorrect grade.
Poor joint treatment.
Rain before adequate film formation may damage certain water-based acrylic coatings.
Low temperature, high humidity or unsuitable drying conditions may prevent proper film development.
Some acrylic coatings are not approved for prolonged standing water.
A product specifically tested for the intended exposure should be selected.
| Standard | Application |
|---|---|
| Applicable EAD for Liquid-Applied Roof Waterproofing Kits | Assessment of relevant roof waterproofing systems |
| ASTM D6083/D6083M | Liquid-applied acrylic coating used in roofing |
| ASTM D412 | Tensile properties of elastomeric materials, where applicable |
| ASTM D4541 | Pull-off strength of coatings |
| ISO 2808 | Film thickness determination |
| ISO 2811-1 | Density determination |
| ISO 3251 | Non-volatile matter content |
| ASTM C1549 | Solar reflectance measurement, where applicable |
| ASTM C1371 | Thermal emittance measurement, where applicable |
Compliance depends on the product and its intended application. Test standards should not be presented as certifications without supporting manufacturer documentation.
Buyers should confirm:
Roof, terrace or wall application.
Exposed or protected system.
Water-based or other formulation.
Elastomeric performance.
UV resistance.
Ponding water resistance.
Required dry film thickness.
Tensile strength.
Elongation.
Crack-bridging performance.
Adhesion.
Primer compatibility.
Substrate moisture limits.
Reinforcement.
Solar reflectance requirements.
Packaging.
Project quantity.
Acrylic waterproofing coatings are commonly supplied in pails or drums.
Consumption depends on:
Surface area.
Substrate porosity.
Volume solids.
Required dry film thickness.
Number of coats.
Reinforcement.
Application losses.
Theoretical wet consumption (L/m²) = Required dry film thickness (mm) ÷ Volume solids fraction
For example, a coating with an assumed 55% volume solids applied at a total dry film thickness of 1.0 mm requires approximately 1.82 L/m² before losses.
For a 300 m² roof:
Theoretical quantity: approximately 546 litres.
With an illustrative 10% allowance: approximately 601 litres.
These figures are calculation examples, not a product coverage claim. Actual consumption must follow the selected manufacturer’s technical data.
Yaseen Construction Products can review sourcing enquiries against relevant acrylic roof waterproofing and elastomeric coating systems from approved manufacturers.
Technical comparisons should consider:
Acrylic polymer formulation.
Solids content.
Required dry film thickness.
UV resistance.
Ponding water resistance.
Elongation.
Crack bridging.
Adhesion.
Reflectivity where applicable.
Intended application.
Equivalent products must be matched to the actual project specification rather than product name alone.
Pricing depends on:
Acrylic formulation.
Solids content.
Performance grade.
UV resistance.
Reflective properties.
Required membrane thickness.
Manufacturer.
Packaging.
Order quantity.
Delivery destination.
For accurate comparisons, evaluate the installed coating cost per square metre at the required dry film thickness.
For a specification-based quotation, provide:
Project location.
Roof, terrace, wall or other application.
Substrate type.
Exposed or protected system.
Required dry film thickness.
UV and ponding water requirements.
Applicable technical standard.
Surface area.
Primer and reinforcement requirements.
Required quantity.
Packaging preference.
Delivery destination.
Delivery schedule.
Yaseen Construction Products supplies and exports acrylic waterproofing coatings for roofs, terraces, parapet walls, concrete surfaces and approved exterior waterproofing systems across the UAE, Saudi Arabia, Qatar, Oman, Kuwait and African countries, including Nigeria, Kenya, Ghana, Tanzania, Uganda, Ethiopia, South Africa, Egypt, Morocco, Rwanda, Zambia, Mozambique and Senegal.
We support roofing contractors, waterproofing specialists, civil engineering companies, property developers, commercial construction companies and procurement teams with specification-based sourcing, bulk quotations and international shipment arrangements.
Product availability, pricing and delivery schedules depend on formulation, packaging, quantity and destination.
Seamless Application: Forms a continuous coating across properly prepared open surfaces.
Elastomeric Options: Suitable formulations provide flexibility and tested elongation.
UV-Resistant Grades: Selected products are designed for exposed roof applications.
Reflective Finishes: Approved grades offer specified solar reflectance and thermal emittance.
Water-Based Options: Many acrylic coatings use water as the principal carrier.
Concrete Compatibility: Suitable products adhere to properly prepared concrete surfaces.
Roof Refurbishment: Approved systems can be used over compatible existing roof surfaces.
Complex Detail Coverage: Liquid application supports corners, upstands and drainage details.
Reinforcement Compatibility: Selected systems incorporate approved fabrics at critical locations.
Application Flexibility: Products may support brush, roller or spray application.
Thickness-Based Specification: Coating requirements can be calculated using dry film thickness.
Bulk Project Supply: Suitable for commercial roofing, residential developments and exterior protection projects.
Flat Roofs: Waterproofing of approved flat and low-slope roof systems.
Terraces: Protective waterproofing for suitable terrace surfaces.
Concrete Roof Slabs: Liquid-applied waterproofing of prepared concrete.
Parapet Walls: Protection of roof upstands and wall junctions.
Exterior Walls: Weather protection using suitable elastomeric acrylic grades.
Metal Roofs: Approved acrylic coating systems for compatible metal substrates.
Roof Refurbishment: Recoating of compatible existing waterproofing systems.
Residential Buildings: Waterproofing for villas and apartment developments.
Commercial Buildings: Roof and exterior waterproofing.
Industrial Buildings: Roof protection for warehouses and factories.
Institutional Buildings: Roofing applications for schools, hospitals and similar facilities.
Roof Drainage Details: Reinforced coating around approved outlets and penetrations.
Acrylic Waterproofing Coating is a liquid-applied polymer material that forms a protective film after drying and curing. Suitable grades are used to waterproof roofs, terraces and other approved building surfaces.
It is used for roof waterproofing, terrace protection, concrete roof slabs, parapet walls, exterior surfaces and selected roof refurbishment applications.
Suitable acrylic waterproofing systems provide resistance to water penetration when applied at the specified thickness and fully cured. The coating must be approved for the intended exposure, including any standing water conditions.
Yes. Acrylic coatings are commonly used in approved flat and low-slope roof systems. Drainage, UV exposure, substrate movement and ponding water resistance must be considered.
Many exterior-grade acrylic coatings are formulated for UV exposure. The level of resistance depends on the product and should be confirmed through manufacturer data.
Reflective acrylic roof coatings may reduce roof surface temperature under suitable conditions. Actual performance depends on solar reflectance, thermal emittance, climate and roof construction. Energy savings should not be assumed without supporting calculations.
Acrylic coatings commonly form a film through water evaporation and polymer coalescence. Polyurethane coatings use different polymer chemistry and curing mechanisms. Their flexibility, UV resistance, moisture tolerance and waterproofing performance depend on the formulation.
Yes. Suitable acrylic coatings can be applied to properly prepared concrete. The substrate must meet the manufacturer’s requirements for curing, moisture, surface strength and cleanliness.
Some acrylic systems are approved for compatible existing roofing materials. Surface condition, adhesion, moisture and primer requirements must be checked before application.
The number of coats depends on the product and specified dry film thickness. Multiple coats are commonly used, but the manufacturer’s application instructions determine the correct system.
Consumption depends on volume solids and required dry film thickness. For example, a coating with an assumed 55% volume solids applied at 1.0 mm dry film thickness requires approximately 1.82 litres/m² before losses. Actual coverage must follow the selected manufacturer’s data.
Yaseen Construction Products supplies and exports acrylic waterproofing coatings for roofs, terraces, parapet walls, concrete surfaces and approved exterior waterproofing applications across the UAE, Saudi Arabia, Qatar, Oman, Kuwait and African countries, including Nigeria, Kenya, Ghana, Tanzania, Uganda, Ethiopia, South Africa, Egypt, Morocco, Rwanda, Zambia, Mozambique and Senegal.
We assist roofing contractors, waterproofing specialists, civil engineering companies, property developers and procurement teams with specification-based sourcing, bulk quotations and international shipment arrangements.
Trusted supplier and exporter of building construction products in UAE, Saudi, Qatar, Oman & African Countries.
Still confused?
We are happy to help on our expertise with no conditions.